skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Time Sensitive Chemicals

Authors:
 [1]
  1. Los Alamos National Laboratory
Publication Date:
Research Org.:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1418776
Report Number(s):
LA-UR-18-20535
DOE Contract Number:
AC52-06NA25396
Resource Type:
Conference
Resource Relation:
Conference: Operational Events Forum Meeting ; 2018-01-22 - 2018-01-22 ; Los Alamos, New Mexico, United States
Country of Publication:
United States
Language:
English

Citation Formats

Bridgewater, Jon S. Time Sensitive Chemicals. United States: N. p., 2018. Web.
Bridgewater, Jon S. Time Sensitive Chemicals. United States.
Bridgewater, Jon S. 2018. "Time Sensitive Chemicals". United States. doi:. https://www.osti.gov/servlets/purl/1418776.
@article{osti_1418776,
title = {Time Sensitive Chemicals},
author = {Bridgewater, Jon S.},
abstractNote = {},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = 2018,
month = 1
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share:
  • We describe a prototype trace gas sensor designed for real-time detection of multiple chemicals. The sensor uses an external cavity quantum cascade laser (ECQCL) swept over its tuning range of 940-1075 cm-1 (9.30-10.7 ┬Ám) at a 10 Hz repetition rate.
  • A new method for recording beam-foil time-of-flight data is described. A stationary, side-window, position-senstive proportional counter, oriented with anode wire parallel to the ion beam, views the decay in flight of excited ions through a Soller slit x-ray collimator. In contrast to the standard method, the exciter foil, placed within or upstream from the field of view, is not moved during the acquisition of a decay curve. Each point on the anode acts like an independent detector seeing a unique segment of the ion beam. The correspondence between the downstream distance at which an ion decays and the position alongmore » the anode at which the x-ray is detected makes a pulse-height spectrum of position pulses equivalent to a time-of-flight decay curve. Thus an entire decay curve can now be acquired without moving the foil. Increased efficiency is the most significant improvement over the standard method in which the radiation detector views only a small segment of the flight path at any one time. Experiments using translating foils are subject to a spurious dependence of x-ray intensity on foil position if the foil is non-uniform (or non-uniformly aged) and wobbles as it moves. This effect is eliminated here. Foil aging effects which influence excitation rates and introduce a slowly varying time dependence of the x-ray intensity are automatically normalized by this multichannel technique. The application of this method to metastable x-ray emitting states of low-Z ions are discussed.« less
  • An amplifier with trapezoidal pulse shaping was developed for high-rate high-energy gamma spectroscopy using NaI(T1) scintillation detectors. It employs a double delay-line technique for producing a nearly triangular pulse shape combined with a linear circuit for producing a flattopped pulse. Good energy resolution and short resolving time make this amplifier especially suitable for high count rate gamma ray spectroscopy. To provide a versatile high-performance system, it includes a pileup rejector based on inspection of a pileup signal obtained by combining the slow output signal and fast-shaped input signal. The trapezoidal shape provides a short resolving time for minimal occurrence ofmore » pileup with a width suitable for presentation to a standard multichannel analyzer. The performance of the system was tested, and the results are presented.« less
  • This paper reports on a new position-sensitive time-of-flight neutron detection and histograming system developed for use at the Intense Pulsed Neutron Source. Spatial resolution of roughly 1 cm {times} 1 cm and time-of-flight resolution of {approximately} 1 {mu}sec are combined in a detection system which can ultimately be expanded to cover several square meters of active detector area. This system is based on the use of arrays of cylindrical one-dimensional position-sensitive proportional counters, and is capable of collecting the x-y-t data and sorting them into histograms at time-averaged data rates up to {approximately} 300,000 events/sec over the full detector areamore » and with instantaneous data rates up to more than fifty times that. Numerous hardware features have been incorporated to facilitate initial tuning of the position encoding, absolute calibration of the encoded positions, and automatic testing for drifts.« less
  • Researchers in robot vision have access to several excellent image processing packages (e.g., Khoros, Vista, Susan, MIL, and X Vision to name only a few) as a base for any new vision software needed in most navigation and recognition tasks. Our work in automonous robot control and human-robot interaction, however, has demanded a new level of run-time flexibility and performance: on-the-fly configuration of visual routines that exploit up-to-the-second context from the task, image, and environment. The result is Gargoyle: an extendible, on-board, real-time vision software package that allows a robot to configure, parameterize, and execute image-processing pipelines at run-time. Eachmore » operator in a pipeline works at a level of resolution and over regions of interest that are computed by upstream operators or set by the robot according to task constraints. Pipeline configurations and operator parameters can be stored as a library of visual methods appropriate for different sensing tasks and environmental conditions. Beyond this, a robot may reason about the current task and environmental constraints to construct novel visual routines that are too specialized to work under general conditions, but that are well-suited to the immediate environment and task. We use the RAP reactive plan-execution system to select and configure pre-compiled processing pipelines, and to modify them for specific constraints determined at run-time.« less