skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Ion Mobility Spectrometer Field Test

Technical Report ·
DOI:https://doi.org/10.2172/1418326· OSTI ID:1418326
 [1];  [1];  [1]
  1. Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division

The Morpho Saffran Itemizer 4DX Ion Mobility Spectrometer previously used to detect uranium signatures in FY16 was used at the former New Brunswick Facility, a past uranium facility located on site at Argonne National Laboratory. This facility was chosen in an attempt to detect safeguards relevant signatures and has a history of processing uranium at various enrichments, chemical forms, and purities; various chemicals such as nitric acid, uranium fluorides, phosphates and metals are present at various levels. Several laboratories were sampled for signatures of nuclear activities around the laboratory. All of the surfaces that were surveyed were below background levels of the radioanalytical instrumentation and determined to be radiologically clean.

Research Organization:
Argonne National Lab. (ANL), Argonne, IL (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation
DOE Contract Number:
AC02-06CH11357
OSTI ID:
1418326
Report Number(s):
ANL/NE-17/16; 138669
Country of Publication:
United States
Language:
English