Abstract

The Morpho Saffran Itemizer 4DX Ion Mobility Spectrometer previously used to detect uranium signatures in FY16 was used at the former New Brunswick Facility, a past uranium facility located on site at Argonne National Laboratory. This facility was chosen in an attempt to detect safeguards relevant signatures and has a history of processing uranium at various enrichments, chemical forms, and purities; various chemicals such as nitric acid, uranium fluorides, phosphates and metals are present at various levels. Several laboratories were sampled for signatures of nuclear activities around the laboratory. All of the surfaces that were surveyed were below background levels of the radioanalytical instrumentation and determined to be radiologically clean.

Authors:
 [1];  [1];  [1]
  1. Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division
Publication Date:
Research Org.:
Argonne National Lab. (ANL), Argonne, IL (United States)
Sponsoring Org.:
USDOE National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation
OSTI Identifier:
1418326
Report Number(s):
ANL/NE-17/16
138669
DOE Contract Number:  
AC02-06CH11357
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 36 MATERIALS SCIENCE; 98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL PROTECTION

Citation Formats

Smith, Nicholas, McLain, Derek, and Steeb, Jennifer. Ion Mobility Spectrometer Field Test. United States: N. p., 2017. Web. doi:10.2172/1418326.
Smith, Nicholas, McLain, Derek, & Steeb, Jennifer. Ion Mobility Spectrometer Field Test. United States. https://doi.org/10.2172/1418326
Smith, Nicholas, McLain, Derek, and Steeb, Jennifer. 2017. "Ion Mobility Spectrometer Field Test". United States. https://doi.org/10.2172/1418326. https://www.osti.gov/servlets/purl/1418326.
@article{osti_1418326,
title = {Ion Mobility Spectrometer Field Test},
author = {Smith, Nicholas and McLain, Derek and Steeb, Jennifer},
abstractNote = {The Morpho Saffran Itemizer 4DX Ion Mobility Spectrometer previously used to detect uranium signatures in FY16 was used at the former New Brunswick Facility, a past uranium facility located on site at Argonne National Laboratory. This facility was chosen in an attempt to detect safeguards relevant signatures and has a history of processing uranium at various enrichments, chemical forms, and purities; various chemicals such as nitric acid, uranium fluorides, phosphates and metals are present at various levels. Several laboratories were sampled for signatures of nuclear activities around the laboratory. All of the surfaces that were surveyed were below background levels of the radioanalytical instrumentation and determined to be radiologically clean.},
doi = {10.2172/1418326},
url = {https://www.osti.gov/biblio/1418326}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Dec 20 00:00:00 EST 2017},
month = {Wed Dec 20 00:00:00 EST 2017}
}