Abstract

The RELAP5-3D computer code has been assessed using data from Test PG 22 in Oregon State University’s High Temperature Test Facility. Test PG 22 investigated the gas exchange between the primary coolant system helium and the reactor cavity simulation tank nitrogen following a heatup from ambient temperature. The heatup was terminated when the coolant temperature rise across the core reached 125°C. The code generally under predicted coolant and structure temperatures, likely the result of under predicting the core temperature and stored energy during the initial heatup, although there were no measured values to compare with. A full-loop natural circulation flow that occurred in the test was not predicted in any of the simulations.

Authors:
 [1];  [1]
  1. Idaho National Lab. (INL), Idaho Falls, ID (United States)
Publication Date:
Research Org.:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
Sponsoring Org.:
USDOE Office of Nuclear Energy (NE)
OSTI Identifier:
1408761
Report Number(s):
INL/EXT-17-43120
DOE Contract Number:  
AC07-05ID14517
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; 97 MATHEMATICS AND COMPUTING; code assessment; High Temperature Test Facility; RELAP5-3D

Citation Formats

Bayless, Paul D., and Forsmann, J. Hope. RELAP5-3D Assessment Using High Temperature Test Facility Test PG-22. United States: N. p., 2017. Web. doi:10.2172/1408761.
Bayless, Paul D., & Forsmann, J. Hope. RELAP5-3D Assessment Using High Temperature Test Facility Test PG-22. United States. doi:10.2172/1408761.
Bayless, Paul D., and Forsmann, J. Hope. Thu . "RELAP5-3D Assessment Using High Temperature Test Facility Test PG-22". United States. doi:10.2172/1408761. https://www.osti.gov/servlets/purl/1408761.
@article{osti_1408761,
title = {RELAP5-3D Assessment Using High Temperature Test Facility Test PG-22},
author = {Bayless, Paul D. and Forsmann, J. Hope},
abstractNote = {The RELAP5-3D computer code has been assessed using data from Test PG 22 in Oregon State University’s High Temperature Test Facility. Test PG 22 investigated the gas exchange between the primary coolant system helium and the reactor cavity simulation tank nitrogen following a heatup from ambient temperature. The heatup was terminated when the coolant temperature rise across the core reached 125°C. The code generally under predicted coolant and structure temperatures, likely the result of under predicting the core temperature and stored energy during the initial heatup, although there were no measured values to compare with. A full-loop natural circulation flow that occurred in the test was not predicted in any of the simulations.},
doi = {10.2172/1408761},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2017},
month = {9}
}