skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Quantum Sensing Beyond the Shot-Noise Limit with Plasmonic Sensors

Authors:
 [1];  [1];  [1]; ORCiD logo [2]; ORCiD logo [2]
  1. University of Oklahoma, Norman
  2. ORNL
Publication Date:
Research Org.:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1407752
DOE Contract Number:
AC05-00OR22725
Resource Type:
Conference
Resource Relation:
Conference: 48th Annual Meeting of the APS Division of Atomic, Molecular and Optical Physics - Sacremento, California, United States of America - 6/5/2017 4:00:00 AM-6/9/2017 4:00:00 AM
Country of Publication:
United States
Language:
English

Citation Formats

Dowran, M., Marino, Alberto, Kumar, Ashok, Pooser, Raphael C., and Lawrie, Benjamin J.. Quantum Sensing Beyond the Shot-Noise Limit with Plasmonic Sensors. United States: N. p., 2017. Web.
Dowran, M., Marino, Alberto, Kumar, Ashok, Pooser, Raphael C., & Lawrie, Benjamin J.. Quantum Sensing Beyond the Shot-Noise Limit with Plasmonic Sensors. United States.
Dowran, M., Marino, Alberto, Kumar, Ashok, Pooser, Raphael C., and Lawrie, Benjamin J.. 2017. "Quantum Sensing Beyond the Shot-Noise Limit with Plasmonic Sensors". United States. doi:. https://www.osti.gov/servlets/purl/1407752.
@article{osti_1407752,
title = {Quantum Sensing Beyond the Shot-Noise Limit with Plasmonic Sensors},
author = {Dowran, M. and Marino, Alberto and Kumar, Ashok and Pooser, Raphael C. and Lawrie, Benjamin J.},
abstractNote = {},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = 2017,
month = 6
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share:
  • Plasmonic sensors are important detectors of biochemical trace compounds, but those that utilize optical readout are approaching their absolute limits of detection as defined by the Heisenberg uncertainty principle in both differential intensity and phase readout. However, the use of more general minimum uncertainty states in the form of squeezed light can push the noise floor in these sensors below the shot noise limit (SNL) in one analysis variable at the expense of another. Here, we demonstrate a quantum plasmonic sensor whose noise floor is reduced below the SNL in order to perform index of refraction measurements with sensitivities unobtainablemore » with classical plasmonic sensors. The increased signal-to-noise ratio can result in faster detection of analyte concentrations that were previously lost in the noise. As a result, these benefits are the hallmarks of a sensor exploiting quantum readout fields in order to manipulate the limits of the Heisenberg uncertainty principle.« less
  • Entangled states can potentially be used to outperform the standard quantum limit by which every classical sensor is bounded. However, entangled states are very susceptible to decoherence, and so it is not clear whether one can really create a superior sensor to classical technology via a quantum strategy which is subject to the effect of realistic noise. This paper presents an investigation of how a quantum sensor composed of many spins is affected by independent dephasing. We adopt general noise models including non-Markovian effects, and in these noise models the performance of the sensor depends crucially on the exposure timemore » of the sensor to the field. We have found that, by choosing an appropriate exposure time within the non-Markovian time region, an entangled sensor does actually beat the standard quantum limit. Since independent dephasing is one of the most typical sources of noise in many systems, our results suggest a practical and scalable approach to beating the standard quantum limit.« less
  • A series of dc SQUIDs has been fabricated in an attempt to obtain quantum-limited sensitivity. Typically, the SQUID inductance, L, is 2 pH, the capacitance and critical current of each tunnel junction are 0.5 pF and 0.5 mA, and the shunt resistance for each junction is 1..cap omega... The measured spectral density of the voltage noise S/sub v/ contains a l/f component that extends typically to 100 kHz or higher. When the l/f component is subtracted out, the best energy sensitivity achieved to date is epsilon/1Hz = S/sub v//2L(delta V/delta PHI)/sup 2/ less than or approximately equal to 2h, wheremore » delta V/delta PHI is the transfer coefficient.« less
  • Extremely sensitive gas sensors can be fabricated using heterostructures of the form metal-sensing layer-semiconductor or metal-sensing layer-metal. These structures are heterostructure diodes which have the barrier controlling transport at least partially located in the sensing layer. In the presence of the gas species to be detected, the electrical properties of the sensing layer evolve, resulting in a modification of the barrier to electric current transport and, hence, resulting in detection due to changes in the current-voltage characteristics of the device. This type of sensor structure is demonstrated using the Pd/Ti-O/sub x/Ti heterostructure hydrogen detector.