Title: Parametric Criticality Safety Calculations for Arrays of TRU Waste Containers

Abstract

The Nuclear Criticality Safety Division (NCSD) has performed criticality safety calculations for finite and infinite arrays of transuranic (TRU) waste containers. The results of these analyses may be applied in any technical area onsite (e.g., TA-54, TA-55, etc.), as long as the assumptions herein are met. These calculations are designed to update the existing reference calculations for waste arrays documented in Reference 1, in order to meet current guidance on calculational methodology.

Authors:
 [1]
  1. Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
Publication Date:
Research Org.:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1406190
Report Number(s):
LA-UR-17-29824
DOE Contract Number:
AC52-06NA25396
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES

Citation Formats

Gough, Sean T. Parametric Criticality Safety Calculations for Arrays of TRU Waste Containers. United States: N. p., 2017. Web. doi:10.2172/1406190.
Gough, Sean T. Parametric Criticality Safety Calculations for Arrays of TRU Waste Containers. United States. doi:10.2172/1406190.
Gough, Sean T. Thu . "Parametric Criticality Safety Calculations for Arrays of TRU Waste Containers". United States. doi:10.2172/1406190. https://www.osti.gov/servlets/purl/1406190.
@article{osti_1406190,
title = {Parametric Criticality Safety Calculations for Arrays of TRU Waste Containers},
author = {Gough, Sean T.},
abstractNote = {The Nuclear Criticality Safety Division (NCSD) has performed criticality safety calculations for finite and infinite arrays of transuranic (TRU) waste containers. The results of these analyses may be applied in any technical area onsite (e.g., TA-54, TA-55, etc.), as long as the assumptions herein are met. These calculations are designed to update the existing reference calculations for waste arrays documented in Reference 1, in order to meet current guidance on calculational methodology.},
doi = {10.2172/1406190},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Oct 26 00:00:00 EDT 2017},
month = {Thu Oct 26 00:00:00 EDT 2017}
}

Technical Report: