Chapter 9: Metering Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy-Efficiency Savings for Specific Measures
- ADM Associates, Inc. Sacramento, CA (United States)
Estimated energy savings are calculated as the difference between the energy use during the baseline period and the energy use during the post installation period of the EEM. This chapter describes the physical properties measured in the process of evaluating EEMs and the specific metering methods for several types of measurements. Skill-level requirements and other operating considerations are discussed, including where, when, and how often measurements should be made. The subsequent section identifies metering equipment types and their respective measurement accuracies. This is followed by sections containing suggestions regarding proper data handling procedures and the categorization and definition of several load types.