skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Sensitivity Variation on Low Cycle Fatigue Cracks Using Level 4/Method B Penetrant

Abstract

The Federal Aviation Administration's Airworthiness Assurance NDI Validation Center (AANC) is currently conducting experiments with Level 4, Method B penetrant on low cycle fatigue specimens. The main focus of these experiments is to document the affect on penetrant brightness readings by varying inspection parameters. This paper discusses the results of changing drying temperature, drying time, and dwell time of both penetrant and emulsifier on low cycle fatigue specimens.

Authors:
;
Publication Date:
Research Org.:
Sandia National Labs., Albuquerque, NM (US); Sandia National Labs., Livermore, CA (US)
Sponsoring Org.:
US Department of Energy (US)
OSTI Identifier:
13982
Report Number(s):
SAND99-2238C
TRN: AH200135%%524
DOE Contract Number:  
AC04-94AL85000
Resource Type:
Conference
Resource Relation:
Conference: 1999 Fall Conference and Quality Testing Show American Society of Nondestructive Testing, Phoenix, AZ (US), 10/11/1999--10/15/1999; Other Information: PBD: 2 Sep 1999
Country of Publication:
United States
Language:
English
Subject:
42 ENGINEERING; AIRCRAFT; LIQUID PENETRANT INSPECTION; SENSITIVITY; VALIDATION; FATIGUE; PERFORMANCE; DRYING; SAMPLE PREPARATION

Citation Formats

FULWOOD,HARRY, and MOORE,DAVID G. Sensitivity Variation on Low Cycle Fatigue Cracks Using Level 4/Method B Penetrant. United States: N. p., 1999. Web.
FULWOOD,HARRY, & MOORE,DAVID G. Sensitivity Variation on Low Cycle Fatigue Cracks Using Level 4/Method B Penetrant. United States.
FULWOOD,HARRY, and MOORE,DAVID G. Thu . "Sensitivity Variation on Low Cycle Fatigue Cracks Using Level 4/Method B Penetrant". United States. https://www.osti.gov/servlets/purl/13982.
@article{osti_13982,
title = {Sensitivity Variation on Low Cycle Fatigue Cracks Using Level 4/Method B Penetrant},
author = {FULWOOD,HARRY and MOORE,DAVID G.},
abstractNote = {The Federal Aviation Administration's Airworthiness Assurance NDI Validation Center (AANC) is currently conducting experiments with Level 4, Method B penetrant on low cycle fatigue specimens. The main focus of these experiments is to document the affect on penetrant brightness readings by varying inspection parameters. This paper discusses the results of changing drying temperature, drying time, and dwell time of both penetrant and emulsifier on low cycle fatigue specimens.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1999},
month = {9}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: