skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: THERMOCHEMICAL MODEL OF INTUMESCING FIRE PROTECTION COATING.

Abstract

Abstract not provided.

Authors:
; ; ; ; ;
Publication Date:
Research Org.:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
Sponsoring Org.:
USDOE National Nuclear Security Administration (NNSA)
OSTI Identifier:
1394042
Report Number(s):
SAND2016-9107C
647406
DOE Contract Number:
AC04-94AL85000
Resource Type:
Conference
Resource Relation:
Conference: Proposed for presentation at the 2nd Thermal and Fluid Engineering Conference held April 2-5, 2017 in Las Vegas, NV.
Country of Publication:
United States
Language:
English

Citation Formats

Larsen, Marvin E., Reinholz, Emilee Lolita, Coker, Eric Nicholas, Jameson, Kevin Jay, Hoffmeister, Kathryn N. Gabet, and Adee, Shane Michael. THERMOCHEMICAL MODEL OF INTUMESCING FIRE PROTECTION COATING.. United States: N. p., 2016. Web.
Larsen, Marvin E., Reinholz, Emilee Lolita, Coker, Eric Nicholas, Jameson, Kevin Jay, Hoffmeister, Kathryn N. Gabet, & Adee, Shane Michael. THERMOCHEMICAL MODEL OF INTUMESCING FIRE PROTECTION COATING.. United States.
Larsen, Marvin E., Reinholz, Emilee Lolita, Coker, Eric Nicholas, Jameson, Kevin Jay, Hoffmeister, Kathryn N. Gabet, and Adee, Shane Michael. 2016. "THERMOCHEMICAL MODEL OF INTUMESCING FIRE PROTECTION COATING.". United States. doi:. https://www.osti.gov/servlets/purl/1394042.
@article{osti_1394042,
title = {THERMOCHEMICAL MODEL OF INTUMESCING FIRE PROTECTION COATING.},
author = {Larsen, Marvin E. and Reinholz, Emilee Lolita and Coker, Eric Nicholas and Jameson, Kevin Jay and Hoffmeister, Kathryn N. Gabet and Adee, Shane Michael},
abstractNote = {Abstract not provided.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = 2016,
month = 9
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share:
  • The living fire probabilistic risk assessment (PRA) models for all three operating nuclear power plants (NPPs) in Taiwan had been established in December 2000. In that study, a scenario-based PRA approach was adopted to systematically evaluate the fire and smoke hazards and associated risks. Using these fire PRA models developed, a risk-informed application project had also been completed in December 2002 for the evaluation of cable-tray fire-barrier wrapping exemption. This paper presents a new application of the fire PRA models to fire protection issues using the fire protection significance determination process (FP SDP). The fire protection issues studied may involvemore » the selection of appropriate compensatory measures during the period when an automatic fire detection or suppression system in a safety-related fire zone becomes inoperable. The compensatory measure can either be a 24-hour fire watch or an hourly fire patrol. The living fire PRA models were used to estimate the increase in risk associated with the fire protection issue in terms of changes in core damage frequency (CDF) and large early release frequency (LERF). In compliance with SDP at-power and the acceptance guidelines specified in RG 1.174, the fire protection issues in question can be grouped into four categories; red, yellow, white and green, in accordance with the guidelines developed for FD SDP. A 24-hour fire watch is suggested only required for the yellow condition, while an hourly fire patrol may be adopted for the white condition. More limiting requirement is suggested for the red condition, but no special consideration is needed for the green condition. For the calculation of risk measures, risk impacts from any additional fire scenarios that may have been introduced, as well as more severe initiating events and fire damages that may accompany the fire protection issue should be considered carefully. Examples are presented in this paper to illustrate the evaluation process. (authors)« less
  • A previously described acid-base model for thermochemical water splitting cycles is applied to cycles based upon reactions of manganese oxides. Experiments confirmed that at least 12 acids - HCl, H/sub 2/SO/sub 4/, H/sub 3/PO/sub 4/, MoO/sub 3/, NaPO/sub 3/, Na/sub 4/P/sub 2/O/sub 7/, SiO/sub 2/, Cr/sub 2/O/sub 3/, TiO/sub 2/, Al/sub 2/O/sub 3/, SnO/sub 2/, and Fe/sub 2/0/sub 3/ - drive the thermal decomposition of NaMnO/sub 2/ at temperatures below 1400 K. Only rather strong bases - NaOH, LiOH, BaO, Li/sub 2/CO/sub 3/, Na/sub 2/CO/sub 3/, NaCO/sub 3/ - can drive the steam oxidation of Mn(II) below 1300 K. Inmore » accord with the model, the acids HCl, H/sub 2/SO/sub 4/, H/sub 3/PO/sub 4/, and MoO/sub 3/ are too strong to be used in Mn(III)/(II) cycles, because their Na, Li, and Ba salts are too stable. Cycles were demonstrated with the other 8 acids and either NaOH or Na/sub 2/CO/sub 3/. Because such cycles evolve O/sub 2/(g) in the presence of air, solar furnaces are appropriate sources of thermal energy for them.« less
  • A mechanistic successional model, FIRE-BGC (a FIRE BioGeoChemical succession model), has been developed to investigate the role of fire and climate on long-term landscape dynamics in northern Rocky Mountain coniferous forests. This FIRE-BGC application explicitly simulates fire behavior and effects on landscape characteristics. Predictions of evapotranspiration are contrasted with and without fire over 200 years of simulation for the McDonald Drainage, Glacier National Park under current climate conditions are provided as an example of the potential of FIRE-BGC.
  • A comparison of the KAMELEON Fire model to large-scale open pool fire experimental data is presented. The model was used to calculate large-scale JP-4 pool fires with and without wind, and with and without large objects in the fire. The effect of wind and large objects on the fire environment is clearly seen. For the pool fire calculations without any object in the fire, excellent agreement is seen in the location of the oxygen-starved region near the pool center. Calculated flame temperatures are about 200--300 K higher than measured. This results in higher heat fluxes back to the fuel poolmore » and higher fuel evaporation rates (by a factor of 2). Fuel concentrations at lower elevations and peak soot concentrations are in good agreement with data. For pool fire calculations with objects, similar trends in the fire environment are observed. Excellent agreement is seen in the distribution of the heat flux around a cylindrical calorimeter in a rectangular pool with wind effects. The magnitude of the calculated heat flux to the object is high by a factor of 2 relative to the test data, due to the higher temperatures calculated. For the case of a large flat plate adjacent to a circular pool, excellent qualitative agreement is seen in the predicted and measured flame shapes as a function of wind.« less