Title: Development of a high resolution x-ray spectrometer for the National Ignition Facility (NIF)

Conference ·
DOI:https://doi.org/10.1063/1.4962053· OSTI ID:1390005

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC52-07NA27344
OSTI ID:
1390005
Report Number(s):
LLNL-CONF-737717
Resource Relation:
Journal Volume: 87; Journal Issue: 11; Conference: Presented at: High Temperature Plasma Diagnostics (21st Topical Conference), Madison, WI, United States, Jun 05 - Jun 09, 2016
Country of Publication:
United States
Language:
English

References (9)

Cretin—a radiative transfer capability for laboratory plasmas journal October 2001
A focusing X-ray crystal spectrograph journal February 1984
Röntgenspektroskopie und Abbildung mittels gekrümmter Kristallreflektoren. I. Geometrisch-optische Betrachtungen journal January 1933
FLYCHK: Generalized population kinetics and spectral model for rapid spectroscopic analysis for all elements journal December 2005
Bent crystal spectrometer for both frequency and wavenumber resolved x-ray scattering at a seeded free-electron laser journal September 2014
Validation of modelled imaging plates sensitivity to 1-100 keV x-rays and spatial resolution characterisation for diagnostics for the “PETawatt Aquitaine Laser” journal April 2016
Measurement of high-energy (10–60 keV) x-ray spectral line widths with eV accuracy journal November 2014
High performance imaging streak camera for the National Ignition Facility journal December 2012
A multi-cone x-ray imaging Bragg crystal spectrometer journal August 2016

Cited By (1)

Absolute calibration of a time-resolved high resolution x-ray spectrometer for the National Ignition Facility (invited) journal October 2018