skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: DIM and diagnostic placement for NIF experiments

Abstract

The input that has been provided on the NIF experiment setup sheets has allowed us to review the diagnostic and DIM placement as well as the baseline unconverted light management plan. We have done an iteration to identify common diagnostic lines of sight, and with additional requirements defined by specific experiments, we propose (1) a baseline plan for DIM placement requiring only five DIMs that may be moved between up to seven DIM ports, and (2) a modified baseline unconverted light management plan. We request additional input to identify primary vs. secondary diagnostics for each experiment definition.

Authors:
Publication Date:
Research Org.:
Lawrence Livermore National Lab., CA (US)
Sponsoring Org.:
USDOE Office of Defense Programs (DP) (US)
OSTI Identifier:
13899
Report Number(s):
UCRL-ID-135801; DP0210000
DP0210000; TRN: US0110835
DOE Contract Number:  
W-7405-ENG-48
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 14 Sep 1999
Country of Publication:
United States
Language:
English
Subject:
70 PLASMA PHYSICS AND FUSION TECHNOLOGY; US NATIONAL IGNITION FACILITY; OPERATION; PLASMA DIAGNOSTICS; RADIATION MONITORS; POSITIONING

Citation Formats

Kalantar, D. DIM and diagnostic placement for NIF experiments. United States: N. p., 1999. Web. doi:10.2172/13899.
Kalantar, D. DIM and diagnostic placement for NIF experiments. United States. doi:10.2172/13899.
Kalantar, D. Tue . "DIM and diagnostic placement for NIF experiments". United States. doi:10.2172/13899. https://www.osti.gov/servlets/purl/13899.
@article{osti_13899,
title = {DIM and diagnostic placement for NIF experiments},
author = {Kalantar, D},
abstractNote = {The input that has been provided on the NIF experiment setup sheets has allowed us to review the diagnostic and DIM placement as well as the baseline unconverted light management plan. We have done an iteration to identify common diagnostic lines of sight, and with additional requirements defined by specific experiments, we propose (1) a baseline plan for DIM placement requiring only five DIMs that may be moved between up to seven DIM ports, and (2) a modified baseline unconverted light management plan. We request additional input to identify primary vs. secondary diagnostics for each experiment definition.},
doi = {10.2172/13899},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1999},
month = {9}
}

Technical Report:

Save / Share: