skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Directional Spectrometer Software.

Abstract

Abstract not provided.

Authors:
Publication Date:
Research Org.:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
Sponsoring Org.:
USDOE National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation (NA-20)
OSTI Identifier:
1378836
Report Number(s):
SAND2016-8339PE
646913
DOE Contract Number:
AC04-94AL85000
Resource Type:
Conference
Resource Relation:
Conference: Proposed for presentation at the Weapons and Material Security held September 20-22, 2016 in Livermore, CA.
Country of Publication:
United States
Language:
English

Citation Formats

Horne, Steven M. Directional Spectrometer Software.. United States: N. p., 2016. Web.
Horne, Steven M. Directional Spectrometer Software.. United States.
Horne, Steven M. 2016. "Directional Spectrometer Software.". United States. doi:. https://www.osti.gov/servlets/purl/1378836.
@article{osti_1378836,
title = {Directional Spectrometer Software.},
author = {Horne, Steven M.},
abstractNote = {Abstract not provided.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = 2016,
month = 8
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share:
  • Abstract not provided.
  • Abstract not provided.
  • Most mass spectrometer data systems are developed and optimized for the benchtop GC/MS market and thus do not adequately address the requirements for direct sampling methods. Field analysis also places greater demands on real-time data processing including automated interpretation and quantification for target analytes. The current field portable ion trap mass spectrometers developed at ORNL are based on the Finnigan Magnum ion trap mass spectrometer which provides a procedure language for user programs. A series of these procedures has been developed to support direct sampling ion trap mass spectrometry studies and is part of an overall software development strategy tomore » address the needs of these direct sampling instruments for rapid field analysis and process monitoring. The general approach has been to create task oriented menus that lead a user through a complete analysis. Thus, the user is focused on completing tasks rather than learning and using all of the software components to complete the task. Additionally, user input has been minimized to save keyboard input and data logging time.« less
  • There is a strong need for portable radiometric instrumentation that can both accurately confirm the presence of nuclear materials and allow isotopic analysis of radionuclides in the field. To fulfill this need the Safeguards Technology Program at LLNL has developed a hand-held, non-cryogenic, low-power gamma-ray and x-ray measurements and analysis instrument that can both search for and then accurately verify the presence of nuclear materials. We will report on the use of cadmium zinc telluride (CZT) detectors, detector electronics, and the new field-portable instrument being developed. We will also describe the isotopic analysis that allows enrichment measurements to be mademore » accurately in the field. These systems provide capability for safeguards inspection and verification applications and could find application in counter-smuggling operations.« less