skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: GATEWAY Report Brief: Evaluating Tunable LED Lighting in the Swedish Medical Behavioral Health Unit

Abstract

Summary of a GATEWAY report evaluation of a tunable LED lighting system installed in the new Swedish Medical Behavioral Health Unit in Seattle that incorporates color-tunable luminaires in common areas, and uses advanced controls for dimming and color tuning, with the goal of providing a better environment for staff and patients. The report reviews the design of the tunable lighting system, summarizes two sets of measurements, and discusses the circadian, energy, and commissioning implications as well as lessons learned from the project.

Authors:
Publication Date:
Research Org.:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Washington, DC (United States)
Sponsoring Org.:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B) (Solid-State Lighting)
OSTI Identifier:
1378308
Report Number(s):
DOE/EE-1640
7745
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
60 APPLIED LIFE SCIENCES; 59 BASIC BIOLOGICAL SCIENCES; DOE; SSL; LED; GATEWAY; lighting; Seattle; hospital; medical; tuning; color; tunable; circadian; controls; summary

Citation Formats

None, None. GATEWAY Report Brief: Evaluating Tunable LED Lighting in the Swedish Medical Behavioral Health Unit. United States: N. p., 2017. Web. doi:10.2172/1378308.
None, None. GATEWAY Report Brief: Evaluating Tunable LED Lighting in the Swedish Medical Behavioral Health Unit. United States. doi:10.2172/1378308.
None, None. Wed . "GATEWAY Report Brief: Evaluating Tunable LED Lighting in the Swedish Medical Behavioral Health Unit". United States. doi:10.2172/1378308. https://www.osti.gov/servlets/purl/1378308.
@article{osti_1378308,
title = {GATEWAY Report Brief: Evaluating Tunable LED Lighting in the Swedish Medical Behavioral Health Unit},
author = {None, None},
abstractNote = {Summary of a GATEWAY report evaluation of a tunable LED lighting system installed in the new Swedish Medical Behavioral Health Unit in Seattle that incorporates color-tunable luminaires in common areas, and uses advanced controls for dimming and color tuning, with the goal of providing a better environment for staff and patients. The report reviews the design of the tunable lighting system, summarizes two sets of measurements, and discusses the circadian, energy, and commissioning implications as well as lessons learned from the project.},
doi = {10.2172/1378308},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2017},
month = {8}
}

Technical Report:

Save / Share: