Title: PERFORMANCE EVALUATION OF A RESPIRATOR VORTEX COOLING DEVICE

Authors:
;
Publication Date:
Research Org.:
SRS
Sponsoring Org.:
USDOE
OSTI Identifier:
1374400
Report Number(s):
SRNL-STI-2017-00061
DOE Contract Number:
DE-AC09-08SR22470
Resource Type:
Conference
Resource Relation:
Conference: ASME PVP 2017
Country of Publication:
United States
Language:
English

Citation Formats

Elizondo, A., and Iacovone, R. PERFORMANCE EVALUATION OF A RESPIRATOR VORTEX COOLING DEVICE. United States: N. p., 2017. Web.
Elizondo, A., & Iacovone, R. PERFORMANCE EVALUATION OF A RESPIRATOR VORTEX COOLING DEVICE. United States.
Elizondo, A., and Iacovone, R. Thu . "PERFORMANCE EVALUATION OF A RESPIRATOR VORTEX COOLING DEVICE". United States. doi:. https://www.osti.gov/servlets/purl/1374400.
@article{osti_1374400,
title = {PERFORMANCE EVALUATION OF A RESPIRATOR VORTEX COOLING DEVICE},
author = {Elizondo, A. and Iacovone, R.},
abstractNote = {},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Feb 02 00:00:00 EST 2017},
month = {Thu Feb 02 00:00:00 EST 2017}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share:
  • The vortex-tube device provides a useful addition to the range of equipment available to the gas industry. It has been shown that the use of vortex-tube equipment permits improved separation in comparison with a Joule-Thomson system, without entering into the cost and complexity of a true isentropic system such as a turbo-expander unit. The comparative advantage of the vortex tube depends upon the inlet conditions of the gas and the pressure drop that is available. An optimum pressure drop of 25--35% of the inlet gas pressure has been confirmed in practice. Although not yet tested on operating plant, it ismore » expected that a loss of performance of vortex-tube units will occur for inlet liquid-to-gas ratios of greater than 20%. Units with up to 5% liquid at the inlet have been successfully operated showing that a single phase gas at the unit inlet is not essential. It is expected that future application of vortex tube units will be concentrated where performance improvements over Joule-Thomson units, at low capital cost, are required.« less
  • This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heatmore » of electronic components in range from 250 to 740 W.« less
  • A 15-year old, 3-ton single package air-to-air heat pump was tested in laboratory environmental chambers simulating indoor and outdoor conditions. After documenting initial performance, the unit was retrofitted with a prototype condenser water-spray device and retested. Results at standard ARI cooling rating conditions (95 F outdoor dry bulb and 80/67 F indoor dry bulb/wet bulb temperatures) showed the capacity increased by about 7%, and the electric power demand dropped by about 8%, resulting in a steady-state EER increase of 17%. Suction and discharge pressures were reduced by 7 and 37 psi, respectively. A refrigerant oil additive formulated to enhance refrigerant-sidemore » heat transfer was added at a dose of one ounce per ton of rated capacity, and the unit was tested for several days at the same 95 F outdoor conditions and showed essentially no increase in capacity, and a slight 3% increase in steady-state EER. Adding more additive lowered the EER slightly. Suction and discharge pressures were essentially unchanged. The short-term testing showed that the condenser-spray device was effective in increasing the cooling capacity and lowering the electrical demand on an old and relatively inefficient heat pump, but the refrigerant additive had little effect on the cooling performance of the unit. Sprayer issues to be resolved include the effect of a sprayer on a new, high-efficiency air conditioner/heat pump, reliable long-term operation, and economics.« less
  • In 1993, EPRI funded Yankee Atomic Electric Company to examine the effects of respirator use on worker efficiency. Phase I of Yankee`s effort was to develop a study design to determine respirator effects. Given success in Phase I, a larger population will be tested to determine if a stasitically significant respirator effect on performance can be measured. This paper summarizes the 1993 EPRI/Yankee Respirator Effects of Pilot Study, and describes the study design for the 1994 EPRI/Yankee Respirator Study to be conducted at the Oyster Creek Nuclear Power Plant. Also described is a summary of respirator effect studies that havemore » been conducted during the last ten (10) years.« less
  • Two levels of passive/hybrid solar heating and cooling performance evaluation are discussed. They have been reviewed and accepted by coordinating committees drawn from government organizations and universities, as technical appendices to the US DOE Program Area Plan, Performance Evaluation of Passive/Hybrid Solar Heating and Cooling, and will be used in the US DOE passive performance monitoring program. Both levels use a subtractive calculation for passive heating or cooling used by the building, although, with the more detailed method, heat flux to or from primary storage elements is monitored so that an approximate additive calculation can be done.