skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Solvent hold tank sample results for MCU-16-1317-1318-1319: September 2016 monthly sample

Abstract

Savannah River National Laboratory (SRNL) received one set of three Solvent Hold Tank (SHT) samples (MCU-16-1317-1318-1319), pulled on 09/12/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1317-1318-1319 indicated the Isopar™L concentration is above its nominal level (102%). The extractant (MaxCalix) and the modifier (CS-7SB) are 5% and 9% below their nominal concentrations. The suppressor (TiDG) is 76% below its nominal concentration. A summary of the concentration of the relevant solvent components is shown below.

Authors:
 [1];  [1]
  1. Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)
Publication Date:
Research Org.:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1371694
Report Number(s):
SRNL-STI-2016-00684
DOE Contract Number:  
AC09-08SR22470
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CHEMISTRY

Citation Formats

Fondeur, F. F., and Jones, D. H. Solvent hold tank sample results for MCU-16-1317-1318-1319: September 2016 monthly sample. United States: N. p., 2017. Web. doi:10.2172/1371694.
Fondeur, F. F., & Jones, D. H. Solvent hold tank sample results for MCU-16-1317-1318-1319: September 2016 monthly sample. United States. doi:10.2172/1371694.
Fondeur, F. F., and Jones, D. H. Fri . "Solvent hold tank sample results for MCU-16-1317-1318-1319: September 2016 monthly sample". United States. doi:10.2172/1371694. https://www.osti.gov/servlets/purl/1371694.
@article{osti_1371694,
title = {Solvent hold tank sample results for MCU-16-1317-1318-1319: September 2016 monthly sample},
author = {Fondeur, F. F. and Jones, D. H.},
abstractNote = {Savannah River National Laboratory (SRNL) received one set of three Solvent Hold Tank (SHT) samples (MCU-16-1317-1318-1319), pulled on 09/12/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1317-1318-1319 indicated the Isopar™L concentration is above its nominal level (102%). The extractant (MaxCalix) and the modifier (CS-7SB) are 5% and 9% below their nominal concentrations. The suppressor (TiDG) is 76% below its nominal concentration. A summary of the concentration of the relevant solvent components is shown below.},
doi = {10.2172/1371694},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri Jun 16 00:00:00 EDT 2017},
month = {Fri Jun 16 00:00:00 EDT 2017}
}

Technical Report:

Save / Share: