The shear punch testing of irradiated and control MA956 (FeCrAl) Alloy from the NSUF-ATR-UCSB irradiation is presented. This is the first data taken on a new shear punch fixture design to test three 1.5mm punches from each 8mm x 0.5mm Disc Multipurpose Coupon (DMC). Samples were irradiated to 6.1dpa at a temperature of 315°C and 6.2 dpa at 400°C.

Authors:
 [1];  [1];  [1]
  1. Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
Publication Date:
Research Org.:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
Sponsoring Org.:
USDOE Office of Nuclear Energy (NE)
OSTI Identifier:
1363743
Report Number(s):
LA-UR-17-24760
DOE Contract Number:  
AC52-06NA25396
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
36 MATERIALS SCIENCE; Energy Sciences; Material Science

Citation Formats

Saleh, Tarik A., Quintana, Matthew Estevan, and Romero, Tobias J. Shear Punch Testing on ATR Irradiated MA956 FeCrAl Alloy. United States: N. p., 2017. Web. doi:10.2172/1363743.
Saleh, Tarik A., Quintana, Matthew Estevan, & Romero, Tobias J. Shear Punch Testing on ATR Irradiated MA956 FeCrAl Alloy. United States. doi:10.2172/1363743.
Saleh, Tarik A., Quintana, Matthew Estevan, and Romero, Tobias J. Tue . "Shear Punch Testing on ATR Irradiated MA956 FeCrAl Alloy". United States. doi:10.2172/1363743. https://www.osti.gov/servlets/purl/1363743.
@article{osti_1363743,
title = {Shear Punch Testing on ATR Irradiated MA956 FeCrAl Alloy},
author = {Saleh, Tarik A. and Quintana, Matthew Estevan and Romero, Tobias J.},
abstractNote = {The shear punch testing of irradiated and control MA956 (FeCrAl) Alloy from the NSUF-ATR-UCSB irradiation is presented. This is the first data taken on a new shear punch fixture design to test three 1.5mm punches from each 8mm x 0.5mm Disc Multipurpose Coupon (DMC). Samples were irradiated to 6.1dpa at a temperature of 315°C and 6.2 dpa at 400°C.},
doi = {10.2172/1363743},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Jun 13 00:00:00 EDT 2017},
month = {Tue Jun 13 00:00:00 EDT 2017}
}