Title: Correlative imaging across microscopy platforms using the fast and accurate relocation of microscopic experimental regions (FARMER) method

Authors:
 [1]; ORCiD logo [2];  [3];  [2];  [4];  [4]; ORCiD logo [5]
  1. Department of Chemistry, University of Chicago, Chicago, Illinois 60637, USA
  2. Institute for Biophysical Dynamics, University of Chicago, Chicago, Illinois 60637, USA
  3. James Franck Institute, University of Chicago, Chicago, Illinois 60637, USA
  4. Department of Medicine, University of Chicago, Chicago, Illinois 60637, USA
  5. Department of Chemistry, University of Chicago, Chicago, Illinois 60637, USA, Institute for Biophysical Dynamics, University of Chicago, Chicago, Illinois 60637, USA, James Franck Institute, University of Chicago, Chicago, Illinois 60637, USA
Publication Date:
Sponsoring Org.:
USDOE
OSTI Identifier:
1361863
Grant/Contract Number:
AC02-06CH11357
Resource Type:
Journal Article: Publisher's Accepted Manuscript
Journal Name:
Review of Scientific Instruments
Additional Journal Information:
Journal Volume: 88; Journal Issue: 5; Related Information: CHORUS Timestamp: 2018-02-14 20:18:42; Journal ID: ISSN 0034-6748
Publisher:
American Institute of Physics
Country of Publication:
United States
Language:
English

Citation Formats

Huynh, Toan, Daddysman, Matthew K., Bao, Ying, Selewa, Alan, Kuznetsov, Andrey, Philipson, Louis H., and Scherer, Norbert F.. Correlative imaging across microscopy platforms using the fast and accurate relocation of microscopic experimental regions (FARMER) method. United States: N. p., 2017. Web. doi:10.1063/1.4982818.
Huynh, Toan, Daddysman, Matthew K., Bao, Ying, Selewa, Alan, Kuznetsov, Andrey, Philipson, Louis H., & Scherer, Norbert F.. Correlative imaging across microscopy platforms using the fast and accurate relocation of microscopic experimental regions (FARMER) method. United States. doi:10.1063/1.4982818.
Huynh, Toan, Daddysman, Matthew K., Bao, Ying, Selewa, Alan, Kuznetsov, Andrey, Philipson, Louis H., and Scherer, Norbert F.. Mon . "Correlative imaging across microscopy platforms using the fast and accurate relocation of microscopic experimental regions (FARMER) method". United States. doi:10.1063/1.4982818.
@article{osti_1361863,
title = {Correlative imaging across microscopy platforms using the fast and accurate relocation of microscopic experimental regions (FARMER) method},
author = {Huynh, Toan and Daddysman, Matthew K. and Bao, Ying and Selewa, Alan and Kuznetsov, Andrey and Philipson, Louis H. and Scherer, Norbert F.},
abstractNote = {},
doi = {10.1063/1.4982818},
journal = {Review of Scientific Instruments},
number = 5,
volume = 88,
place = {United States},
year = {Mon May 01 00:00:00 EDT 2017},
month = {Mon May 01 00:00:00 EDT 2017}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record at 10.1063/1.4982818

Save / Share:
  • The analysis of a same sample using nanometre or atomic-scale techniques is fundamental to fully understand device properties. This is especially true for the dopant distribution within last generation nano-transistors such as MOSFET or FINFETs. In this work, the spatial distribution of boron in a nano-transistor at the atomic scale has been investigated using a correlative approach combining electron and atom probe tomography. The distortions present in the reconstructed volume using atom probe tomography have been discussed by simulations of surface atoms using a cylindrical symmetry taking into account the evaporation fields. Electron tomography combined with correction of atomic densitymore » was used so that to correct image distortions observed in atom probe tomography reconstructions. These corrected atom probe tomography reconstructions then enable a detailed boron doping analysis of the device.« less
  • Determination of earthquake hypocenter in Indonesia conducted by the Meteorological, Climatological, and Geophysical Agency (MCGA) has still used a 1-D seismic velocity model. In this research, we have applied a Fast Grid Search (FGM) method and a 3-D velocity model resulting from tomographic imaging to relocate earthquakes in the Sumatran region. The data were taken from the MCGA data catalog from 2009 to 2011 comprising of subduction zone and on land fault earthquakes with magnitude greater than 4 Mw. Our preliminary results show some significant changes in the depths of the relocated earthquakes which are in general deeper than themore » depths of hypocenters from the MCGA data catalog. The residual times resulting from the relocation process are smaller than those prior to the relocation. Encouraged by these results, we will continue to conduct hypocenter relocation for all events from the MCGA data catalog periodically in order to produce a new data catalog with good quality. We hope that the new data catalog will be useful for further studies.« less
  • Magnetotactic bacteria biomineralize ordered chains of uniform, membrane-bound magnetite or greigite nanocrystals that exhibit nearly perfect crystal structures and species-specific morphologies. Transmission electron microscopy (TEM) is a critical technique for providing information regarding the organization of cellular and magnetite structures in these microorganisms. However, conventional TEM can only be used to image air-dried or vitrified bacteria removed from their natural environment. Here we present a correlative scanning TEM (STEM) and fluorescence microscopy technique for imaging viable cells of Magnetospirillum magneticum strain AMB-1 in liquid using an in situ fluid cell TEM holder. Fluorescently labeled cells were immobilized on microchip windowmore » surfaces and visualized in a fluid cell with STEM, followed by correlative fluorescence imaging to verify their membrane integrity. Notably, the post-STEM fluorescence imaging indicated that the bacterial cell wall membrane did not sustain radiation damage during STEM imaging at low electron dose conditions. We investigated the effects of radiation damage and sample preparation on the bacteria viability and found that approximately 50% of the bacterial membranes remained intact after an hour in the fluid cell, decreasing to ~30% after two hours. These results represent a first step toward in vivo studies of magnetite biomineralization in magnetotactic bacteria.« less
  • Nanocrystalline ceria exhibits a total conductivity several orders of magnitude higher than microcrystalline ceria in air at high temperature. The most widely accepted theory for this enhancement (based on fitting of conductivity data to various transport and kinetic models) is that relatively immobile positively charged defects and/or impurities accumulate at the grain boundary core, leading to a counterbalancing increase in the number of mobile electrons (small polarons) within a diffuse space charge region adjacent to each grain boundary. In an effort to validate this model, we have applied electrochemical strain microscopy to image the location and relative population of mobilemore » electrons near grain boundaries in polycrystalline Sm-doped ceria in air at 20–200 °C. Our results show the first direct (spatially resolved) evidence that such a diffuse space charge region does exist in ceria, and is localized to both grain boundaries and the gas-exposed surface.« less
  • A wide variety of focal and diffuse infectious processes involve the abdomen. At one extreme are diseases such as pyelonephritis, cystitis, and pelvic inflammatory disease, conditions usually diagnosed without imaging studies and treated without complications. At the other extreme are abdominal abscesses, which may defy clinical diagnosis, are associated with significant morbidity and mortality, and may remain undetected or insufficiently characterized in spite of multiple imaging studies. The limited diagnostic value of clinical evaluation and plain film radiography in abscess detection has lead to widespread use of sophisticated imaging techniques including Gallium-67 (67Ga) scintigraphy, Indium-111 WBC (111In-WBC) scintigraphy, computed tomographymore » (CT), and ultrasonography (US). Abdominal abscesses occur in a wide variety of anatomic sites, may involve any abdominal organ system, and have a number of different causes. The heterogeneity of the disease process and the varying capabilities of the different imaging techniques (with respect to site and organ system) make reliance on a single technique undesirable. An algorithmic approach using 67Ga or 111In-WBC scintigraphy, CT, and US provides a logical and clinically practical approach to complicated abdominal infection. By recognizing differences in clinical presentation and by appreciating the diagnostic strengths and weaknesses of nuclear medicine, CT, and US, the algorithm provides a reliable and direct route to accurate diagnosis while minimizing unnecessary examinations.« less