Title: Versatile, ultra-low sample volume gas analyzer using a rapid, broad-tuning ECQCL and a hollow fiber gas cell

Abstract

We describe a versatile mid-infrared (Mid-IR) spectroscopy system developed to measure the concentration of a wide range of gases with an ultra-low sample size. The system combines a rapidly-swept external cavity quantum cascade laser (ECQCL) with a hollow fiber gas cell. The ECQCL has sufficient spectral resolution and reproducibility to measure gases with narrow features (e.g., water, methane, ammonia, etc.), and also the spectral tuning range needed to measure volatile organic compounds (VOCs), (e.g., aldehydes, ketones, hydrocarbons), sulfur compounds, chlorine compounds, etc. The hollow fiber is a capillary tube having an internal reflective coating optimized for transmitting the Mid-IR laser beam to a detector. Sample gas introduced into the fiber (e.g., internal volume = 0.6 ml) interacts strongly with the laser beam, and despite relatively modest path lengths (e.g., L ~ 3 m), the requisite quantity of sample needed for sensitive measurements can be significantly less than what is required using conventional IR laser spectroscopy systems. Example measurements are presented including quantification of VOCs relevant for human breath analysis with a sensitivity of ~2 picomoles at a 1 Hz data rate.

Authors:
; ; ; ; ; ;
Publication Date:
Research Org.:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1358510
Report Number(s):
PNNL-SA-125504
453060031
DOE Contract Number:
AC05-76RL01830
Resource Type:
Conference
Resource Relation:
Conference: Next-Generation Spectroscopic Technologies X, April 9, 2017, Anaheim, California. Proceedings of the SPIE, 10210:Article No. 1021003
Country of Publication:
United States
Language:
English
Subject:
spectroscopy; broad-tuning; ECQCL; c

Citation Formats

Kriesel, Jason M., Makarem, Camille N., Phillips, Mark C., Moran, James J., Coleman, Max, Christensen, Lance, and Kelly, James F. Versatile, ultra-low sample volume gas analyzer using a rapid, broad-tuning ECQCL and a hollow fiber gas cell. United States: N. p., 2017. Web. doi:10.1117/12.2262612.
Kriesel, Jason M., Makarem, Camille N., Phillips, Mark C., Moran, James J., Coleman, Max, Christensen, Lance, & Kelly, James F. Versatile, ultra-low sample volume gas analyzer using a rapid, broad-tuning ECQCL and a hollow fiber gas cell. United States. doi:10.1117/12.2262612.
Kriesel, Jason M., Makarem, Camille N., Phillips, Mark C., Moran, James J., Coleman, Max, Christensen, Lance, and Kelly, James F. Fri . "Versatile, ultra-low sample volume gas analyzer using a rapid, broad-tuning ECQCL and a hollow fiber gas cell". United States. doi:10.1117/12.2262612.
@article{osti_1358510,
title = {Versatile, ultra-low sample volume gas analyzer using a rapid, broad-tuning ECQCL and a hollow fiber gas cell},
author = {Kriesel, Jason M. and Makarem, Camille N. and Phillips, Mark C. and Moran, James J. and Coleman, Max and Christensen, Lance and Kelly, James F.},
abstractNote = {We describe a versatile mid-infrared (Mid-IR) spectroscopy system developed to measure the concentration of a wide range of gases with an ultra-low sample size. The system combines a rapidly-swept external cavity quantum cascade laser (ECQCL) with a hollow fiber gas cell. The ECQCL has sufficient spectral resolution and reproducibility to measure gases with narrow features (e.g., water, methane, ammonia, etc.), and also the spectral tuning range needed to measure volatile organic compounds (VOCs), (e.g., aldehydes, ketones, hydrocarbons), sulfur compounds, chlorine compounds, etc. The hollow fiber is a capillary tube having an internal reflective coating optimized for transmitting the Mid-IR laser beam to a detector. Sample gas introduced into the fiber (e.g., internal volume = 0.6 ml) interacts strongly with the laser beam, and despite relatively modest path lengths (e.g., L ~ 3 m), the requisite quantity of sample needed for sensitive measurements can be significantly less than what is required using conventional IR laser spectroscopy systems. Example measurements are presented including quantification of VOCs relevant for human breath analysis with a sensitivity of ~2 picomoles at a 1 Hz data rate.},
doi = {10.1117/12.2262612},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri May 05 00:00:00 EDT 2017},
month = {Fri May 05 00:00:00 EDT 2017}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share:
  • The morphologies of advanced asymmetric gas separation membranes can be described in terms of porosity, pore size distribution, and pore connectivity. These complex morphologies are generated via a rapid non-solvent induced phase separation process to yield hollow fiber membranes. Manipulation and control of these microscopic features are accomplished through adjustment of an array of spinning process parameters. A serious limitation to research in hollow fiber membrane formation is the lengthy time lag between fiber spinning and the collection of characteristic data for process optimization. This lag time is due to the intensive downstream processing required before gas based permeation measurementsmore » can be conducted. A rapid feedback characterization technique will be discussed for use in polymeric hollow fiber membrane spinning applications utilizing commercially available disperse dyes. This technique involves dyeing wet hollow fibers immediately after spinning in an aqueous dye bath. In the present work, polysulfone fibers have been characterized using this method before lengthy downstream processing (i.e. solvent exchange, drying, and post-treatment). Dye uptake in the hollow fibers appears to be a function of skin porosity, thereby allowing quick evaluation of permeation characteristics. Dye uptake was measured both visually and using UV-visible spectrophotometry. Examples of fibers characterized using this technique and relationships between dye uptake and post-treated selectivity are shown and discussed. This technique allows characterization during the fiber spinning process, making on-line optimization of spinning parameters possible.« less
  • No abstract prepared.
  • Abstract not provided.
  • In the thermometer, radiation from a target is collected via a single 700 {mu}m-bore hollow glass optical fiber coated with a metallic/dielectric layer on the inner surface, simultaneously split into two paths and modulated by a Au-coated reflective chopper, and focused onto two thermoelectrically cooled mid-infrared HgCdZnTe photoconductors by 128.8 mm-radius Au-coated spherical mirrors. The photoconductors have spectral bandpasses of 2-6 {mu}m and 2.12 {mu}m, respectively. The modulated detector signals are recovered using lock- in amplification. The two signals are calibrated using a blackbody (emissivity=1) of known temperature, and exponential fits are applied to the two resulting voltage vs temperaturemore » curves. Using the two calibration equations, a computer algorithm calculates the temperature and emissivity of a target in real time, taking into account reflection of the background radiation field from the target surface.« less
  • The microstructure and surface chemistry of PPG microporous hollow fiber silica membranes was investigated by a variety of methods including FTIR spectroscopy, physical adsorption of Ar, and small angle X-ray scattering (SAXS). FTIR spectroscopy was utilized to monitor the amount of water in the silica membranes as a function of temperature and pressure. By annealing the membrane to 700 K, and then dosing with water vapor, the authors demonstrated that removal of physically adsorbed water is reversible. The pore size distribution of the silica fibers was determined by measuring the physical adsorption of Ar at 87 K. Since the Kelvinmore » equation does not apply to pore sizes of molecular dimensions, the pore sizes were determined by using the Horvath-Kawazoe (H-K) potential function. The calculated average pore diameters were 5.5 {angstrom} for a 6 {angstrom} zeolite and 8.2 {angstrom} for the PPG fiber sample. By calculating the average pore diameter for the zeolite with a known structure, the authors were able to demonstrate that the H-K potential function predicts pore diameters within 10% of the actual pore diameter from the zeolite structure. In addition to the physical adsorption measurements, SAXS experiments were performed to acquire the pore size distribution of the fibers. By assuming the pores are spherical voids, an average pore size of approximately 13 {angstrom} was calculated. Changing the angle of incidence of the X-rays resulted in no detectable change in the intensity of the transmitted X-rays, indicating that the pores are oriented in a completely random configuration. High selectivities were obtained for O{sub 2}/N{sub 2} and CO{sub 2}/CH{sub 4} mixtures.« less