skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Probing water distribution in compressed fuel-cell gas-diffusion layers using X-ray computed tomography

; ; ; ORCiD logo
Publication Date:
Sponsoring Org.:
USDOE Office of Energy Efficiency and Renewable Energy (EERE)
OSTI Identifier:
Resource Type:
Journal Article: Publisher's Accepted Manuscript
Journal Name:
Electrochemistry Communications
Additional Journal Information:
Journal Volume: 53; Journal Issue: C; Related Information: CHORUS Timestamp: 2017-05-17 09:12:10; Journal ID: ISSN 1388-2481
Country of Publication:

Citation Formats

Zenyuk, Iryna V., Parkinson, Dilworth Y., Hwang, Gisuk, and Weber, Adam Z. Probing water distribution in compressed fuel-cell gas-diffusion layers using X-ray computed tomography. Netherlands: N. p., 2015. Web. doi:10.1016/j.elecom.2015.02.005.
Zenyuk, Iryna V., Parkinson, Dilworth Y., Hwang, Gisuk, & Weber, Adam Z. Probing water distribution in compressed fuel-cell gas-diffusion layers using X-ray computed tomography. Netherlands. doi:10.1016/j.elecom.2015.02.005.
Zenyuk, Iryna V., Parkinson, Dilworth Y., Hwang, Gisuk, and Weber, Adam Z. 2015. "Probing water distribution in compressed fuel-cell gas-diffusion layers using X-ray computed tomography". Netherlands. doi:10.1016/j.elecom.2015.02.005.
title = {Probing water distribution in compressed fuel-cell gas-diffusion layers using X-ray computed tomography},
author = {Zenyuk, Iryna V. and Parkinson, Dilworth Y. and Hwang, Gisuk and Weber, Adam Z.},
abstractNote = {},
doi = {10.1016/j.elecom.2015.02.005},
journal = {Electrochemistry Communications},
number = C,
volume = 53,
place = {Netherlands},
year = 2015,
month = 4

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record at 10.1016/j.elecom.2015.02.005

Citation Metrics:
Cited by: 35works
Citation information provided by
Web of Science

Save / Share:
  • We present an experimental approach to study the three-dimensional microstructure of gas diffusion layer (GDL) materials under realistic compression conditions. A dedicated compression device was designed that allows for synchrotron-tomographic investigation of circular samples under well-defined compression conditions. The tomographic data provide the experimental basis for stochastic modeling of nonwoven GDL materials. A plain compression tool is used to study the fiber courses in the material at different compression stages. Transport relevant geometrical parameters, such as porosity, pore size, and tortuosity distributions, are exemplarily evaluated for a GDL sample in the uncompressed state and for a compression of 30 vol.%.more » To mimic the geometry of the flow-field, we employed a compression punch with an integrated channel-rib-profile. It turned out that the GDL material is homogeneously compressed under the ribs, however, much less compressed underneath the channel. GDL fibers extend far into the channel volume where they might interfere with the convective gas transport and the removal of liquid water from the cell.« less
  • Purpose: Magnetic resonance imaging/diffusion weighted-imaging (MRI/DWI)-guided high-dose-rate (HDR) brachytherapy and {sup 18}F-fluorodeoxyglucose (FDG) — positron emission tomography/computed tomography (PET/CT)-guided intensity modulated radiation therapy (IMRT) for the definitive treatment of cervical cancer is a novel treatment technique. The purpose of this study was to report our analysis of dose-volume parameters predicting gross tumor volume (GTV) control. Methods and Materials: We analyzed the records of 134 patients with International Federation of Gynecology and Obstetrics stages IB1-IVB cervical cancer treated with combined MRI-guided HDR and IMRT from July 2009 to July 2011. IMRT was targeted to the metabolic tumor volume and lymph nodesmore » by use of FDG-PET/CT simulation. The GTV for each HDR fraction was delineated by use of T2-weighted or apparent diffusion coefficient maps from diffusion-weighted sequences. The D100, D90, and Dmean delivered to the GTV from HDR and IMRT were summed to EQD2. Results: One hundred twenty-five patients received all irradiation treatment as planned, and 9 did not complete treatment. All 134 patients are included in this analysis. Treatment failure in the cervix occurred in 24 patients (18.0%). Patients with cervix failures had a lower D100, D90, and Dmean than those who did not experience failure in the cervix. The respective doses to the GTV were 41, 58, and 136 Gy for failures compared with 67, 99, and 236 Gy for those who did not experience failure (P<.001). Probit analysis estimated the minimum D100, D90, and Dmean doses required for ≥90% local control to be 69, 98, and 260 Gy (P<.001). Conclusions: Total dose delivered to the GTV from combined MRI-guided HDR and PET/CT-guided IMRT is highly correlated with local tumor control. The findings can be directly applied in the clinic for dose adaptation to maximize local control.« less
  • Purpose: One major uncertainty in radiotherapy planning of non-small-cell lung cancer concerns the definition of the clinical target volume (CTV), meant to cover potential microscopic disease extension (MDE) around the macroscopically visible tumor. The primary aim of this study was to establish pretreatment risk factors for the presence of MDE. The secondary aim was to establish the impact of these factors on the accuracy of positron emission tomography (PET) and computed tomography (CT) to assess the total tumor-bearing region at pathologic examination (CTV{sub path}). Methods and Materials: 34 patients with non-small-cell lung cancer who underwent CT and PET before lobectomymore » were included. Specimens were examined microscopically for MDE. The gross tumor volume (GTV) on CT and PET (GTV{sub CT} and GTV{sub PET}, respectively) was compared with the GTV and the CTV at pathologic examination, tissue deformations being taken into account. Using multivariate logistic regression, image-based risk factors for the presence of MDE were identified, and a prediction model was developed based on these factors. Results: MDE was found in 17 of 34 patients (50%). The MDE did not exceed 26 mm in 90% of patients. In multivariate analysis, two parameters (mean CT tumor density and GTV{sub CT}) were significantly associated with MDE. The area under the curve of the two-parameter prediction model was 0.86. Thirteen tumors (38%, 95% CI: 24-55%) were identified as low risk for MDE, being potential candidates for reduced-intensity therapy around the GTV. In the low-risk group, the effective diameter of the GTV{sub CT/PET} accurately represented the CTV{sub path}. In the high-risk group, GTV{sub CT/PET} underestimated the CTV{sub path} with, on average, 19.2 and 26.7 mm, respectively. Conclusions: CT features have potential to predict the presence of MDE. Tumors identified as low risk of MDE show lower rates of disease around the GTV than do high-risk tumors. Both CT and PET accurately visualize the CTV{sub path} in low-risk tumors but underestimate it in high-risk tumors.« less
  • Purpose: To assess the predictive value of {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) for disease recurrence after immunochemotherapy (R-CHT) and mediastinal irradiation (RT), using the recently published criteria of the Lugano classification to predict outcomes for patients with primary mediastinal large B-cell lymphoma. Methods and Materials: Among 125 patients prospectively enrolled in the IELSG-26 study, 88 were eligible for central review of PET/CT scans after completion of RT. Responses were evaluated using the 5-point Deauville scale at the end of induction R-CHT and after consolidation RT. According to the Lugano classification, a complete metabolic response (CMR) was defined bymore » a Deauville score (DS) ≤3. Results: The CMR (DS1, -2, or -3) rate increased from 74% (65 patients) after R-CHT to 89% (78 patients) after consolidation RT. Among the 10 patients (11%) with persistently positive scans, the residual uptake after RT was slightly higher than the liver uptake in 6 patients (DS4; 7%) and markedly higher in 4 patients (DS5; 4%): these patients had a significantly poorer 5-year progression-free survival and overall survival. At a median follow-up of 60 months (range, 35-107 months), no patients with a CMR after RT have relapsed. Among the 10 patients who did not reach a CMR, 3 of the 4 patients (positive predictive value, 75%) with DS5 after RT had subsequent disease progression (within the RT volume in all cases) and died. All patients with DS4 had good outcomes without recurrence. Conclusions: All the patients obtaining a CMR defined as DS ≤3 remained progression-free at 5 years, confirming the excellent negative predictive value of the Lugano classification criteria in primary mediastinal large B-cell lymphoma patients. The few patients with DS4 also had an excellent outcome, suggesting that they do not necessarily require additional therapy, because the residual {sup 18}F-fluorodeoxyglucose uptake may not reflect persistent lymphoma.« less
  • An understanding of Lithium (Li) spatial distribution within the electrodes of a Li-ion cell, during charge and discharge cycles, is essential to optimize the electrode parameters for increased performance under cycling. In this work, it is demonstrated that the spatial distribution of Li within Vanadium Pentoxide (V 2O 5) electrodes of a small coin cell can be imaged by neutron computed tomography. The neutron attenuation data has been used to construct the three-dimensional Li spatial images. Specifically, it is shown that there is sufficient neutron imaging contrast between lithiated and delithiated regions of V 2O 5 electrode making it possiblemore » to map Li distributions even in small electrodes with thicknesses <1 mm. The images reveal that the Li spatial distribution is inhomogeneous and a relatively higher C-rate leads to more non-uniform Li distribution after Li insertion. The non-uniform distribution suggests the limitation of Li diffusion within the electrode during the lithiation process under the relatively high cycling rates.« less