skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: CALiPER Report 22.1: Photoelectric Performance of LED MR16 Lamps

Abstract

This report is a follow-up to CALiPER Application Summary Report 22, which investigated the photometric performance of LED MR16 lamps. The initial report found that many of the LED MR16 lamps did not perform as required by ENERGY STAR based on their equivalency claims, although they generally did provide substantial efficacy advantages compared to halogen MR16 lamps. All testing was completed using laboratory power supplies, with all but one product tested at 12 V AC. In contrast, this report examined the photoelectric performance of the same set of lamps, using commercially available transformers and dimmers as well as laboratory power supplies providing both AC and DC power.

Authors:
 [1];  [1];  [1];  [1]
  1. Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Publication Date:
Research Org.:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1355128
Report Number(s):
PNNL-24627
BT0301000
DOE Contract Number:
AC05-76RL01830
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; LEDs; photoelectric; MR16; flicker; dimming

Citation Formats

Royer, Michael P., Poplawski, Michael E., Brown, Charles C., and Merzouk, Massine B.. CALiPER Report 22.1: Photoelectric Performance of LED MR16 Lamps. United States: N. p., 2015. Web. doi:10.2172/1355128.
Royer, Michael P., Poplawski, Michael E., Brown, Charles C., & Merzouk, Massine B.. CALiPER Report 22.1: Photoelectric Performance of LED MR16 Lamps. United States. doi:10.2172/1355128.
Royer, Michael P., Poplawski, Michael E., Brown, Charles C., and Merzouk, Massine B.. Tue . "CALiPER Report 22.1: Photoelectric Performance of LED MR16 Lamps". United States. doi:10.2172/1355128. https://www.osti.gov/servlets/purl/1355128.
@article{osti_1355128,
title = {CALiPER Report 22.1: Photoelectric Performance of LED MR16 Lamps},
author = {Royer, Michael P. and Poplawski, Michael E. and Brown, Charles C. and Merzouk, Massine B.},
abstractNote = {This report is a follow-up to CALiPER Application Summary Report 22, which investigated the photometric performance of LED MR16 lamps. The initial report found that many of the LED MR16 lamps did not perform as required by ENERGY STAR based on their equivalency claims, although they generally did provide substantial efficacy advantages compared to halogen MR16 lamps. All testing was completed using laboratory power supplies, with all but one product tested at 12 V AC. In contrast, this report examined the photoelectric performance of the same set of lamps, using commercially available transformers and dimmers as well as laboratory power supplies providing both AC and DC power.},
doi = {10.2172/1355128},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Sep 01 00:00:00 EDT 2015},
month = {Tue Sep 01 00:00:00 EDT 2015}
}

Technical Report:

Save / Share:
  • This report looks at the photoelectric performance of the same set of lamps assessed in Report 22, using commercially available transformers and dimmers as well as laboratory power supplies providing either AC or DC. The investigation explores several issues related to the testing and use of MR16 lamps in lighting systems and examines the range of performance that is possible for a given lamp model, based on the system to which it is connected.
  • This benchmark report addresses the halogen MR16 lamp and its commercially available light-emitting diode (LED) replacements.
  • An initial sample of 27 LED MR16 lamps and 8 halogen benchmarks underwent photometric testing according to IES LM-79-08. CALiPER Application Summary Report 22 focuses on the initial performance based on light output, efficacy, distribution, color quality, electrical characteristics, and form factor, with comparisons to the benchmarks and ENERGY STAR qualification thresholds.
  • The Department of Energy (DOE) Commercially Available LED Product Evaluation and Reporting (CALiPER) Program was established in 2006 to investigate the performance of light-emitting diode (LED) based luminaires and replacement lamps. To help users better compare LED products with conventional lighting technologies, CALiPER has also performed benchmark research and testing of traditional (i.e., non-LED) lamps and fixtures. This benchmark report addresses standard 4-foot fluorescent lamps (i.e., T12 and T8) and the 2-foot by 4-foot recessed troffers in which they are commonly used. This report also examines available LED replacements for T12 and T8 fluorescent lamps, and their application in fluorescentmore » troffers. The construction and operation of linear fluorescent lamps and troffers are discussed, as well as fluorescent lamp and fixture performance, based on manufacturer data and CALiPER benchmark testing. In addition, the report describes LED replacements for linear fluorescent lamps, and compares their bare lamp and in situ performance with fluorescent benchmarks on a range of standard lighting measures, including power usage, light output and distribution, efficacy, correlated color temperature, and the color rendering index. Potential performance and application issues indicated by CALiPER testing results are also examined.« less
  • This report examines standard fluorescent lamps, the recessed troffers they are commonly used in, and available LED replacements for T12 and T8 fluorescent lamps and their application in fluorescent troffers.