Title: Advanced Testing Method for Ground Thermal Conductivity

Abstract

A new method is developed that can quickly and more accurately determine the effective ground thermal conductivity (GTC) based on thermal response test (TRT) results. Ground thermal conductivity is an important parameter for sizing ground heat exchangers (GHEXs) used by geothermal heat pump systems. The conventional GTC test method usually requires a TRT for 48 hours with a very stable electric power supply throughout the entire test. In contrast, the new method reduces the required test time by 40%–60% or more, and it can determine GTC even with an unstable or intermittent power supply. Consequently, it can significantly reduce the cost of GTC testing and increase its use, which will enable optimal design of geothermal heat pump systems. Further, this new method provides more information about the thermal properties of the GHEX and the ground than previous techniques. It can verify the installation quality of GHEXs and has the potential, if developed, to characterize the heterogeneous thermal properties of the ground formation surrounding the GHEXs.

Authors:
 [1];  [2];  [3]
  1. Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
  2. Geothermal Design Center Inc., Asheville, NC (United States)
  3. Univ. of Tennessee, Knoxville, TN (United States)
Publication Date:
Research Org.:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Building Technologies Research and Integration Center (BTRIC)
Sponsoring Org.:
USDOE Office of Energy Efficiency and Renewable Energy (EERE)
OSTI Identifier:
1354667
Report Number(s):
ORNL/TM-2017/208
ED2701000; CEED509; CRADA/NFE-16-06144
DOE Contract Number:
AC05-00OR22725
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
47 OTHER INSTRUMENTATION

Citation Formats

Liu, Xiaobing, Clemenzi, Rick, and Liu, Su. Advanced Testing Method for Ground Thermal Conductivity. United States: N. p., 2017. Web. doi:10.2172/1354667.
Liu, Xiaobing, Clemenzi, Rick, & Liu, Su. Advanced Testing Method for Ground Thermal Conductivity. United States. doi:10.2172/1354667.
Liu, Xiaobing, Clemenzi, Rick, and Liu, Su. Sat . "Advanced Testing Method for Ground Thermal Conductivity". United States. doi:10.2172/1354667. https://www.osti.gov/servlets/purl/1354667.
@article{osti_1354667,
title = {Advanced Testing Method for Ground Thermal Conductivity},
author = {Liu, Xiaobing and Clemenzi, Rick and Liu, Su},
abstractNote = {A new method is developed that can quickly and more accurately determine the effective ground thermal conductivity (GTC) based on thermal response test (TRT) results. Ground thermal conductivity is an important parameter for sizing ground heat exchangers (GHEXs) used by geothermal heat pump systems. The conventional GTC test method usually requires a TRT for 48 hours with a very stable electric power supply throughout the entire test. In contrast, the new method reduces the required test time by 40%–60% or more, and it can determine GTC even with an unstable or intermittent power supply. Consequently, it can significantly reduce the cost of GTC testing and increase its use, which will enable optimal design of geothermal heat pump systems. Further, this new method provides more information about the thermal properties of the GHEX and the ground than previous techniques. It can verify the installation quality of GHEXs and has the potential, if developed, to characterize the heterogeneous thermal properties of the ground formation surrounding the GHEXs.},
doi = {10.2172/1354667},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Sat Apr 01 00:00:00 EDT 2017},
month = {Sat Apr 01 00:00:00 EDT 2017}
}

Technical Report:

Save / Share:
  • Reillex™ HPQ resin was developed by Los Alamos Laboratory and Reilly Industries Inc. in an effort to increase safety and process efficiency during the recovery and purification of plutonium. Ionac™ A-641, another strong base macroporous anion exchange resin used in the nuclear industry, was known to undergo a runaway reaction in hot nitric acid solutions. Because of this, an extensive amount of thermal analyses testing on the Reillex™ HPQ resin in SRNL was performed in 1999-2001 prior to use. A report on the thermal stability qualification of the Reillex™ HPQ resin in 8M (35%) and 12M (53%) HNO 3 wasmore » reported in 2000. In 2001, the reactivity of Reillex™ HPQ resin in 14.4M (64%) HNO 3 was evaluated. In January of 2001, thermal stability scoping tests were performed on irradiated Reillex™ HPQ resin in 14.4M (64%) HNO 3 (as a worst case scenario) and the results sent to Fauske and Associates to calculate a rupture disk size for the HB-Line resin column. A technical report by Fauske and Associates was issued in February 2001 recommending a 2.0” vent line with a rupture disk set pressure of 60 psig. This calculation was based on ARSST thermal analyses scoping tests at SRNL in which 4 grams of dried resin and 6.0 grams of 64% nitric acid in a 10 gram test cell, produced a maximum pressure rate (dP/dt) of 720 psi/min (12 psi/sec) and a maximum temperature of 250 °C. In 2015, a new batch of Reillex™ HPQ resin was manufactured by Vertellus Industries. A test sample of the resin was sent to SRNL to perform acceptance and qualification thermal stability testing using the ARSST. During these tests, method development was performed to ensure that a representative resin to acid ratios were used while running the tests in the ARSST. Fauske and Associates recommended to either use a full test cell representative of the HB-Line column or a 10 gram sample in the test cell that was representative of the ratios of resin to nitric acid in the actual HB-Line column. An observation was made during method development testing that the 4 grams of resin to 6 grams of 64% acid ratio used in 2001 to determine the rupture disk size did not entirely wet the resin and was not representative of the actual HB-Line column. The results of this study raised questions as to whether the ratio of 4 grams of resin to 6 grams of 64% nitric acid recommended by Fauske and Associates in 2001 was the correct ratio.« less
  • This study establishes the ranges of values of thermal conductivity and thermal diffusivity of the various soils and rocks in the United States and provides this information in a form that can be used in the design of ground-coupled heat pump systems. It presents a simple classification system for use in the identification of soils and rocks by persons not trained in soil mechanics or petrology. This technical document is given practical application in a companion field manual for the identification and classification of thermal conductivity of the various soils and rocks that can be encountered in the United States.more » The field manual, supported by EPRI, was published by the International Ground Source Heat Pump Association. The soil study provides a correlation between thermal resistivity and moisture content. It examines temporal behavior of ambient soil moisture and influence of environmental factors on soil moisture content. It cites factors known to influence soil moisture content, and the National Soil Moisture Study, which provided ambient soil moisture data for a four- to six-year period in six states. It discusses limit states of soil moisture content (field capacity and wilting point) and use of these states to define approximate extremes of ambient soil moisture levels. It proposes a new method of normalization of soil moisture content by its limit states -- the thermal moisture index -- and investigates some of its properties. It uses a mathematical simulator of soil/water hydraulics -- the EPIC model -- to illustrate effects of soil texture, precipitation, and soil temperature on soil moisture under more controlled conditions and with greater geographic coverage than is obtainable from National Soil Moisture Study data. Results of this study demonstrate that four general soil groups can be used to determine earth-loop size (pipe length) for ground-coupled heat pump systems. 48 refs., 162 figs., 26 tabs.« less