skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: The SAS4A/SASSYS-1 Safety Analysis Code System, Version 5

Technical Report ·
DOI:https://doi.org/10.2172/1352187· OSTI ID:1352187
 [1];  [1];  [1]
  1. Argonne National Lab. (ANL), Argonne, IL (United States)

The SAS4A/SASSYS-1 computer code is developed by Argonne National Laboratory for thermal, hydraulic, and neutronic analysis of power and flow transients in liquidmetal- cooled nuclear reactors (LMRs). SAS4A was developed to analyze severe core disruption accidents with coolant boiling and fuel melting and relocation, initiated by a very low probability coincidence of an accident precursor and failure of one or more safety systems. SASSYS-1, originally developed to address loss-of-decay-heat-removal accidents, has evolved into a tool for margin assessment in design basis accident (DBA) analysis and for consequence assessment in beyond-design-basis accident (BDBA) analysis. SAS4A contains detailed, mechanistic models of transient thermal, hydraulic, neutronic, and mechanical phenomena to describe the response of the reactor core, its coolant, fuel elements, and structural members to accident conditions. The core channel models in SAS4A provide the capability to analyze the initial phase of core disruptive accidents, through coolant heat-up and boiling, fuel element failure, and fuel melting and relocation. Originally developed to analyze oxide fuel clad with stainless steel, the models in SAS4A have been extended and specialized to metallic fuel with advanced alloy cladding. SASSYS-1 provides the capability to perform a detailed thermal/hydraulic simulation of the primary and secondary sodium coolant circuits and the balance-ofplant steam/water circuit. These sodium and steam circuit models include component models for heat exchangers, pumps, valves, turbines, and condensers, and thermal/hydraulic models of pipes and plena. SASSYS-1 also contains a plant protection and control system modeling capability, which provides digital representations of reactor, pump, and valve controllers and their response to input signal changes.

Research Organization:
Argonne National Lab. (ANL), Argonne, IL (United States)
Sponsoring Organization:
USDOE Office of Nuclear Energy
DOE Contract Number:
AC02-06CH11357
OSTI ID:
1352187
Report Number(s):
ANL/NE-16/19; 134482
Country of Publication:
United States
Language:
English

Similar Records

Modeling developments for the SAS4A and SASSYS computer codes
Conference · Mon Jan 01 00:00:00 EST 1990 · OSTI ID:1352187

SAS4A/SASSYS-1 VERSION 5.2 SAFETY ANALYSIS CODE SYSTEM
Software · Tue May 09 00:00:00 EDT 2017 · OSTI ID:1352187

The SAS4A/SASSYS-1 Safety Analysis Code System
Software · Tue Jan 31 00:00:00 EST 2012 · OSTI ID:1352187

Related Subjects