skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Aerosol Physics Considerations for Using Cerium Oxide CeO 2 as a Surrogate for Plutonium Oxide PuO 2 in Airborne Release Fraction Measurements for Storage Container Investigations

Abstract

Cerium oxide (CeO2) dust is recommended as a surrogate for plutonium oxide (PuO2) in airborne release fraction experiments. The total range of applicable particle sizes for PuO2 extends from 0.0032 μm (the diameter of a single PuO2 molecule) to 10 μm (the defined upper boundary for respirable particles). For particulates with a physical particle diameter of 1.0 μm, the corresponding aerodynamic diameters for CeO2 and PuO2 are 2.7 μm and 3.4 μm, respectively. Cascade impactor air samplers are capable of measuring the size distributions of CeO2 or PuO2 particulates. In this document, the aerodynamic diameters for CeO2 and PuO2 were calculated for seven different physical diameters (0.0032, 0.02, 0.11, 0.27, 1.0, 3.2, and 10 μm). For cascade impactor measurements, CeO2 and PuO2 particulates with the same physical diameter would be collected onto the same or adjacent collection substrates. The difference between the aerodynamic diameter of CeO2 and PuO2 particles (that have the same physical diameter) is 39% of the resolution of a twelve-stage MSP Inc. 125 cascade impactor, and 34% for an eight-stage Andersen impactor. An approach is given to calculate the committed effective dose (CED) coefficient for PuO2 aerosol particles, compared to a corresponding aerodynamic diameter of CeO2 particles.more » With this approach, use of CeO2 as a surrogate for PuO2 material would follow a direct conversion based on a molar equivalent. In addition to the analytical information developed for this document, several US national labs have published articles about the use of CeO2 as a PuO2 surrogate. Different physical and chemical aspects were considered by these investigators, including thermal properties, ceramic formulations, cold pressing, sintering, molecular reactions, and mass loss in high temperature gas flows. All of those US national lab studies recommended the use of CeO2 as a surrogate material for PuO2.« less

Authors:
 [1];  [1]
  1. Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
Publication Date:
Research Org.:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
Sponsoring Org.:
USDOE National Nuclear Security Administration (NNSA)
OSTI Identifier:
1344345
Report Number(s):
LA-UR-17-21241
DOE Contract Number:
AC52-06NA25396
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL PROTECTION; Radiation Protection; cerium oxide, plutonium oxide, aerosol, respirable

Citation Formats

Moore, Murray E., and Tao, Yong. Aerosol Physics Considerations for Using Cerium Oxide CeO2 as a Surrogate for Plutonium Oxide PuO2 in Airborne Release Fraction Measurements for Storage Container Investigations. United States: N. p., 2017. Web. doi:10.2172/1344345.
Moore, Murray E., & Tao, Yong. Aerosol Physics Considerations for Using Cerium Oxide CeO2 as a Surrogate for Plutonium Oxide PuO2 in Airborne Release Fraction Measurements for Storage Container Investigations. United States. doi:10.2172/1344345.
Moore, Murray E., and Tao, Yong. Thu . "Aerosol Physics Considerations for Using Cerium Oxide CeO2 as a Surrogate for Plutonium Oxide PuO2 in Airborne Release Fraction Measurements for Storage Container Investigations". United States. doi:10.2172/1344345. https://www.osti.gov/servlets/purl/1344345.
@article{osti_1344345,
title = {Aerosol Physics Considerations for Using Cerium Oxide CeO2 as a Surrogate for Plutonium Oxide PuO2 in Airborne Release Fraction Measurements for Storage Container Investigations},
author = {Moore, Murray E. and Tao, Yong},
abstractNote = {Cerium oxide (CeO2) dust is recommended as a surrogate for plutonium oxide (PuO2) in airborne release fraction experiments. The total range of applicable particle sizes for PuO2 extends from 0.0032 μm (the diameter of a single PuO2 molecule) to 10 μm (the defined upper boundary for respirable particles). For particulates with a physical particle diameter of 1.0 μm, the corresponding aerodynamic diameters for CeO2 and PuO2 are 2.7 μm and 3.4 μm, respectively. Cascade impactor air samplers are capable of measuring the size distributions of CeO2 or PuO2 particulates. In this document, the aerodynamic diameters for CeO2 and PuO2 were calculated for seven different physical diameters (0.0032, 0.02, 0.11, 0.27, 1.0, 3.2, and 10 μm). For cascade impactor measurements, CeO2 and PuO2 particulates with the same physical diameter would be collected onto the same or adjacent collection substrates. The difference between the aerodynamic diameter of CeO2 and PuO2 particles (that have the same physical diameter) is 39% of the resolution of a twelve-stage MSP Inc. 125 cascade impactor, and 34% for an eight-stage Andersen impactor. An approach is given to calculate the committed effective dose (CED) coefficient for PuO2 aerosol particles, compared to a corresponding aerodynamic diameter of CeO2 particles. With this approach, use of CeO2 as a surrogate for PuO2 material would follow a direct conversion based on a molar equivalent. In addition to the analytical information developed for this document, several US national labs have published articles about the use of CeO2 as a PuO2 surrogate. Different physical and chemical aspects were considered by these investigators, including thermal properties, ceramic formulations, cold pressing, sintering, molecular reactions, and mass loss in high temperature gas flows. All of those US national lab studies recommended the use of CeO2 as a surrogate material for PuO2.},
doi = {10.2172/1344345},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Feb 16 00:00:00 EST 2017},
month = {Thu Feb 16 00:00:00 EST 2017}
}

Technical Report:

Save / Share: