skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: FLiNaK Compatability Studies with Inconel 600 and Silicon Carbide

Abstract

A small liquid fluoride salt test apparatus has been constructed and testing conducted to examine the compatibility of SiC, Inconel 600, and a spiral wound gasket material in FLiNaK salt. These tests were conducted to test materials and sealing systems that would be used in a FLiNaK salt test loop. Three months of testing at 700oC was used to assure that these materials and seals would be acceptable operating under expected test loop conditions. The SiC specimens showed little or no change over the test period while the spiral wound gasket material showed no degradation, except for the possibility of salt seeping into the outermost spirals of the gasket. The Inconel 600 specimens showed regions of voiding which penetrated the specimen surface to about 250 m in depth. Analysis indicated that the salt had leached chrome from the Inconel surface as was expected for this material. Because the test loop will have a limited working lifetime, it was concluded that these materials would be satisfactory for loop construction.

Authors:
 [1];  [1];  [1];  [2]
  1. Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
  2. Electrochemical Systems, Inc., Knoxville, TN (United States)
Publication Date:
Research Org.:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1340428
Grant/Contract Number:
AC05-00OR22725
Resource Type:
Journal Article: Accepted Manuscript
Journal Name:
Nuclear Engineering and Design
Additional Journal Information:
Journal Volume: 307; Journal ID: ISSN 0029-5493
Publisher:
Elsevier
Country of Publication:
United States
Language:
English
Subject:
42 ENGINEERING; Inconel 600; FLiNaK; Silicon Carbide.compatibility; fluoride salt; molten salt; FHR; MSR

Citation Formats

Yoder, Jr, Graydon L., Heatherly, Dennis Wayne, Wilson, Dane F., and Caja, Mario. FLiNaK Compatability Studies with Inconel 600 and Silicon Carbide. United States: N. p., 2016. Web. doi:10.1016/j.nucengdes.2016.06.037.
Yoder, Jr, Graydon L., Heatherly, Dennis Wayne, Wilson, Dane F., & Caja, Mario. FLiNaK Compatability Studies with Inconel 600 and Silicon Carbide. United States. doi:10.1016/j.nucengdes.2016.06.037.
Yoder, Jr, Graydon L., Heatherly, Dennis Wayne, Wilson, Dane F., and Caja, Mario. 2016. "FLiNaK Compatability Studies with Inconel 600 and Silicon Carbide". United States. doi:10.1016/j.nucengdes.2016.06.037. https://www.osti.gov/servlets/purl/1340428.
@article{osti_1340428,
title = {FLiNaK Compatability Studies with Inconel 600 and Silicon Carbide},
author = {Yoder, Jr, Graydon L. and Heatherly, Dennis Wayne and Wilson, Dane F. and Caja, Mario},
abstractNote = {A small liquid fluoride salt test apparatus has been constructed and testing conducted to examine the compatibility of SiC, Inconel 600, and a spiral wound gasket material in FLiNaK salt. These tests were conducted to test materials and sealing systems that would be used in a FLiNaK salt test loop. Three months of testing at 700oC was used to assure that these materials and seals would be acceptable operating under expected test loop conditions. The SiC specimens showed little or no change over the test period while the spiral wound gasket material showed no degradation, except for the possibility of salt seeping into the outermost spirals of the gasket. The Inconel 600 specimens showed regions of voiding which penetrated the specimen surface to about 250 m in depth. Analysis indicated that the salt had leached chrome from the Inconel surface as was expected for this material. Because the test loop will have a limited working lifetime, it was concluded that these materials would be satisfactory for loop construction.},
doi = {10.1016/j.nucengdes.2016.06.037},
journal = {Nuclear Engineering and Design},
number = ,
volume = 307,
place = {United States},
year = 2016,
month = 7
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record

Citation Metrics:
Cited by: 1work
Citation information provided by
Web of Science

Save / Share:
  • Results presented in this paper demonstrate the roles of the most important parameters that govern abrasive wear of experimental ceramics. SEM studies of the abraded surfaces evidenced two main kinds of failures: microdropping of grain(s) and powder-type wear track(s) resulting from the brittle microfracturing of parts of grain(s). There were whiskers in the surface, and whisker pullouts occurring during wear processes are believed to be the reasons for the lower wear rates of SiCw/Si{sub 3}N{sub 4} composite ceramics under experimental conditions.
  • This paper reports on a ceramic joining technique that has been developed that utilizes an exothermic combustion reaction to simultaneously synthesize the joint interlayer material and to bond together the ceramic workpieces. The method has been used to join SiC ceramics using Ti-C-Ni powder mixtures that ignite below 1200{degrees} C to form a TiC-Ni joining material. Thin layers of the powder reactants were prepared by tape casting, and joining was accomplished by heating in a hot-press to ignite the combustion reaction. during this process, localized exothermic heating of the joint region resulted in chemical interaction at the interface between themore » TiC-Ni and the SiC ceramic that contributed to bonding. Room-temperature four-point bending strengths of joints produced by this method have exceeded 100 MPa.« less
  • Extended x-ray-absorption (EXAFS) and electron-energy-loss fine-structure (EXELFS) measurements have been performed on amorphous unhydrogenated silicon carbide, a-SiC, and amorphous hydrogenated silicon carbide, a-SiC:H. Two hydrogenated samples with hydrogen concentrations corresponding, respectively, to H flows of 4 sccm (20% of argon flow) and 8 sccm (40% of argon flow) during the reactive sputtering process, were analyzed (sccm denotes standard cubic centimeters per minute at STP). It is found that short-range order (SRO), consisting of the same tetrahedrally coordinated units present in cubic crystalline c-SiC (zinc-blende structure), where a Si atom is surrounded by nearly four C atoms and vice versa, doesmore » exist in all the amorphous samples. This SRO, however, is detected only at a level of the first C and Si coordination shells in a-SiC and a-SiC:H. The structural disorder of the first Si and C coordination shells in all forms of amorphous SiC is somewhat greater than c-SiC, and it decreases appreciably as hydrogen is added. The a-SiC sample exhibits large Si and C coordination numbers, almost identical to c-SiC, a low atomic density, and virtually the same Si-C bond length as c-SiC. These results indicate that a relatively small concentration of large voids exist in a highly disordered a-SiC matrix.« less
  • No abstract prepared.