A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data
Journal Article
·
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Brookhaven National Lab. (BNL), Upton, NY (United States)
- SLAC National Accelerator Lab., Menlo Park, CA (United States)
Here, we propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. Finally, the method has been successfully demonstrated on the NSLS-II storage ring.
- Research Organization:
- Brookhaven National Laboratory (BNL), Upton, NY (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), Basic Energy Sciences (BES)
- Grant/Contract Number:
- SC00112704; AC02–98CH10886; AC02–76SF00515
- OSTI ID:
- 1340367
- Alternate ID(s):
- OSTI ID: 1326712
- Report Number(s):
- BNL-112293-2016-JA
- Journal Information:
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 828, Issue C; ISSN 0168-9002
- Publisher:
- ElsevierCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Cited by: 5 works
Citation information provided by
Web of Science
Web of Science
Similar Records
A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data
A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data
Applying Matlab LOCO to the NSLSII Storage Ring Commissioning
Journal Article
·
Mon Aug 01 00:00:00 EDT 2016
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
·
OSTI ID:1340367
A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data
Journal Article
·
Mon Aug 01 00:00:00 EDT 2016
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
·
OSTI ID:1340367
Applying Matlab LOCO to the NSLSII Storage Ring Commissioning
Technical Report
·
Mon Jun 02 00:00:00 EDT 2014
·
OSTI ID:1340367