skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Triple Plate Mold Final Report: Optimization of the Mold Design and Casting Parameters for a Thin U-10mo Fuel Casting

Technical Report ·
DOI:https://doi.org/10.2172/1338724· OSTI ID:1338724
 [1]
  1. Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

This work describes the experiments and modeling that have been performed to improve and try to optimize the simultaneous casting of three plates of U-10wt%Mo in a single coil vacuum induction melting (VIM) furnace. The plates of interest are 280 mm wide by 203 mm tall by 5 mm thick (11" x 8" x 0.2"). The initial mold design and processing parameters were supplied by Y-12. The mold and casting cavity were instrumented with a number of thermocouples, and the casting performed to determine the thermal history of the mold and casting. The resulting cast plates were radiographed and numerous defects identified. Metallography was performed to help identify the nature of the radiographically observed defects. This information was then used to validate a mold filling and solidification model of that casting. Based on the initial casting, good casting design practice, and process simulation of several design alternatives, a revised design was developed with the goal of minimizing casting defects such as porosity. The redesigned mold had a larger hot-top and had its long axis along the horizontal direction. These changes were to try to develop a strong thermal gradient conducive to good feeding and minimization of micro- and macroporosity in the cast plates. An instrumented casting was then performed with the revised mold design and a linear distributor. This design yielded cast plates with significantly less radiographically identified defects. Unfortunately, there was significant variation in plate weight and metal content in their hot-tops. Fluid flow simulations were then performed on this mold/distributor design. This helped identify the issue with this linear distributor design. Additional simulations were then performed on candidate distributor redesigns and a preferred distributor annular design was identified. This improved annular design was used to produce a third instrumented casting with favorable results. These refined designs and their radiographic characterization are compared to the initial design.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
DOE Contract Number:
AC52-06NA25396
OSTI ID:
1338724
Report Number(s):
LA-UR-17-20036
Country of Publication:
United States
Language:
English

Similar Records

Process Development and Optimization of a Direct Cast U-6Nb 250 mm Hemispherical Component
Technical Report · Fri Sep 28 00:00:00 EDT 2018 · OSTI ID:1338724

Effects of Casting Parameters and Impurity Concentrations on As-Cast U–10Mo
Journal Article · Fri Oct 01 00:00:00 EDT 2021 · Progress in Nuclear Energy · OSTI ID:1338724

An Instrumented Uranium Hemispherical Casting
Technical Report · Tue Jan 15 00:00:00 EST 2019 · OSTI ID:1338724