EnergyIQ-the first "action-oriented" benchmarking tool for non-residential buildings-provides a standardized opportunity assessment based on benchmarking results. along with decision-support information to help refine action plans. EnergyIQ offers a wide array of benchmark metrics, with visuall as well as tabular display. These include energy, costs, greenhouse-gas emissions, and a large array of characteristics (e.g. building components or operational strategies). The tool supports cross-sectional benchmarking for comparing the user's building to it's peers at one point in time, as well as longitudinal benchmarking for tracking the performance of an individual building or enterprise portfolio over time. Based on user inputs, the tool generates a list of opportunities and recommended actions. Users can then explore the "Decision Support" module for helpful information on how to refine action plans, create design-intent documentation, and implement improvements. This includes information on best practices, links to other energy analysis tools and more. The variety of databases are available within EnergyIQ from which users can specify peer groups for comparison. Using the tool, this data can be visually browsed and used as a backdrop against which to view a variety of energy benchmarking metrics for the user's own building. User can save their project information and return at a later date to continue their exploration. The initial database is the CA Commercial End-Use Survey (CEUS), which provides details on energy use and characteristics for about 2800 buildings (and 62 building types). CEUS is likely the most thorough survey of its kind every conducted. The tool is built as a web service. The EnergyIQ web application is written in JSP with pervasive us of JavaScript and CSS2. EnergyIQ also supports a SOAP based web service to allow the flow of queries and data to occur with non-browser implementations. Data are stored in an Oracle 10g database. References: Mills, Mathew, Brook and Piette. 2008. "Action Oriented Benchmarking: Concepts and Tools." Energy Engineering, Vol.105, No. 4, pp 21-40. LBNL-358E; Mathew, Mills, Bourassa, Brook. 2008. "Action-Oriented Benchmarking: Using the CEUS Database to Benchmark Commercial Buildings in California." Energy Engineering, Vol 105, No. 5, pp 6-18. LBNL-502E.
To order this software or receive further information, please fill out the following request: Request Software
@misc{osti_1328691,
title = {EnergyIQ, Version 00},
author = {MILLS, EVAN and MATTHE, PAUL and STOUFER, MARTIN},
abstractNote = {EnergyIQ-the first "action-oriented" benchmarking tool for non-residential buildings-provides a standardized opportunity assessment based on benchmarking results. along with decision-support information to help refine action plans. EnergyIQ offers a wide array of benchmark metrics, with visuall as well as tabular display. These include energy, costs, greenhouse-gas emissions, and a large array of characteristics (e.g. building components or operational strategies). The tool supports cross-sectional benchmarking for comparing the user's building to it's peers at one point in time, as well as longitudinal benchmarking for tracking the performance of an individual building or enterprise portfolio over time. Based on user inputs, the tool generates a list of opportunities and recommended actions. Users can then explore the "Decision Support" module for helpful information on how to refine action plans, create design-intent documentation, and implement improvements. This includes information on best practices, links to other energy analysis tools and more. The variety of databases are available within EnergyIQ from which users can specify peer groups for comparison. Using the tool, this data can be visually browsed and used as a backdrop against which to view a variety of energy benchmarking metrics for the user's own building. User can save their project information and return at a later date to continue their exploration. The initial database is the CA Commercial End-Use Survey (CEUS), which provides details on energy use and characteristics for about 2800 buildings (and 62 building types). CEUS is likely the most thorough survey of its kind every conducted. The tool is built as a web service. The EnergyIQ web application is written in JSP with pervasive us of JavaScript and CSS2. EnergyIQ also supports a SOAP based web service to allow the flow of queries and data to occur with non-browser implementations. Data are stored in an Oracle 10g database. References: Mills, Mathew, Brook and Piette. 2008. "Action Oriented Benchmarking: Concepts and Tools." Energy Engineering, Vol.105, No. 4, pp 21-40. LBNL-358E; Mathew, Mills, Bourassa, Brook. 2008. "Action-Oriented Benchmarking: Using the CEUS Database to Benchmark Commercial Buildings in California." Energy Engineering, Vol 105, No. 5, pp 6-18. LBNL-502E.},
doi = {},
url = {https://www.osti.gov/biblio/1328691},
year = {Thu Oct 06 00:00:00 EDT 2016},
month = {Thu Oct 06 00:00:00 EDT 2016},
note =
}