Title: High Efficiency, Low Emission Refrigeration System

Abstract

Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the high refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Methods for reducing refrigerant leakage and energy consumption are available, but underutilized. Further work needs to be done to reduce costs of advanced system designs to improve market utilization. In addition, refrigeration system retrofits that result in reduced energy consumption are needed since the majority of applications address retrofits rather than new stores. The retrofit market is also of most concern since it involves large-volume refrigerant systems with high leak rates. Finally, alternative refrigerants for new and retrofit applications are needed to reduce emissions and reducemore » the impact on the environment. The objective of this Collaborative Research and Development Agreement (CRADA) between the Oak Ridge National Laboratory and Hill Phoenix is to develop a supermarket refrigeration system that reduces greenhouse gas emissions and has 25 to 30 percent lower energy consumption than existing systems. The outcomes of this project will include the design of a low emission, high efficiency commercial refrigeration system suitable for use in current U.S. supermarkets. In addition, a prototype low emission, high efficiency supermarket refrigeration system will be produced for laboratory and field testing. Laboratory and field testing will demonstrate the high energy efficiency and low environmental impact of the refrigeration system developed in this project.« less

Authors:
 [1];  [1]
  1. Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Building Technologies Research and Integration Center
Publication Date:
Research Org.:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Building Technologies Research and Integration Center (BTRIC)
Sponsoring Org.:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B)
OSTI Identifier:
1311267
Report Number(s):
ORNL/TM-2016/363
BT0302000; CEBT002; CRADA/NFE-11-03296
DOE Contract Number:
AC05-00OR22725
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION

Citation Formats

Fricke, Brian A., and Sharma, Vishaldeep. High Efficiency, Low Emission Refrigeration System. United States: N. p., 2016. Web. doi:10.2172/1311267.
Fricke, Brian A., & Sharma, Vishaldeep. High Efficiency, Low Emission Refrigeration System. United States. doi:10.2172/1311267.
Fricke, Brian A., and Sharma, Vishaldeep. Mon . "High Efficiency, Low Emission Refrigeration System". United States. doi:10.2172/1311267. https://www.osti.gov/servlets/purl/1311267.
@article{osti_1311267,
title = {High Efficiency, Low Emission Refrigeration System},
author = {Fricke, Brian A. and Sharma, Vishaldeep},
abstractNote = {Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the high refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Methods for reducing refrigerant leakage and energy consumption are available, but underutilized. Further work needs to be done to reduce costs of advanced system designs to improve market utilization. In addition, refrigeration system retrofits that result in reduced energy consumption are needed since the majority of applications address retrofits rather than new stores. The retrofit market is also of most concern since it involves large-volume refrigerant systems with high leak rates. Finally, alternative refrigerants for new and retrofit applications are needed to reduce emissions and reduce the impact on the environment. The objective of this Collaborative Research and Development Agreement (CRADA) between the Oak Ridge National Laboratory and Hill Phoenix is to develop a supermarket refrigeration system that reduces greenhouse gas emissions and has 25 to 30 percent lower energy consumption than existing systems. The outcomes of this project will include the design of a low emission, high efficiency commercial refrigeration system suitable for use in current U.S. supermarkets. In addition, a prototype low emission, high efficiency supermarket refrigeration system will be produced for laboratory and field testing. Laboratory and field testing will demonstrate the high energy efficiency and low environmental impact of the refrigeration system developed in this project.},
doi = {10.2172/1311267},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Aug 01 00:00:00 EDT 2016},
month = {Mon Aug 01 00:00:00 EDT 2016}
}

Technical Report:

Save / Share:
  • The team of TIAX LLC, ExxonMobil Research and Engineering Company, and Callidus Technologies, LLC conducted a six-year program to develop an ultra-low emission process heater burner and an advanced high efficiency heater design. This project addresses the critical need of process heater operators for reliable, economical emission reduction technologies to comply with stringent emission regulations, and for heater design alternatives that reduce process heater energy requirements without significant cost increase. The key project targets were NOx emissions of 10 ppm (@ 3% O2), and a heater thermal efficiency of 95 percent. The ultra low NOx burner was developed through amore » series of pilot-scale and field tests combined with computational fluid dynamic modeling to arrive at simultaneous low emissions and suitable flame shape and stability. Pilot scale tests were run at TIAX, at the 2 MMBtu/hr scale, and at Callidus at 8 MMBtu/hr. The full scale burner was installed on a 14 burner atmospheric pipestill furnace at an ExxonMobil refinery. A variety of burner configurations, gas tips and flame stabilizers were tested to determine the lowest emissions with acceptable flame shape and stability. The resulting NOx emissions were 22 ppm on average. Starting in 2001, Callidus commercialized the original ultra low NOx burner and made subsequent design improvements in a series of commercial burners evolving from the original concept and/or development. Emissions in the field with the ultra low-NOx burner over a broad spectrum of heater applications have varied from 5 ppm to 30 ppm depending on heater geometry, heater service, fuel and firing capacity. To date, 1550 of the original burners, and 2500 of subsequent generation burners have been sold by Callidus. The advanced heater design was developed by parametric evaluations of a variety of furnace and combustion air preheater configurations and technologies for enhancing convective and radiative heat transfer. The design evolution relied heavily on computational fluid dynamic predictions of design alternatives. The final design features modular separate radiant cells, each with one and two-side fired vertical tubes. The convection section configuration is vertical tube banks enclosed in the radiant channels. Commercial modular plate air preheaters are used. The predicted performance for the integrated advanced heater and Callidus burner is 95 percent efficiency with 9 ppm NOx emissions firing natural gas, and 12 ppm firing refinery gas. The total erected cost is less than a conventional heater with combustion air preheat.« less
  • The objective of the University consortium was to investigate the fundamental processes that determine the practical boundaries of Low Temperature Combustion (LTC) engines and develop methods to extend those boundaries to improve the fuel economy of these engines, while operating with ultra low emissions. This work involved studies of thermal effects, thermal transients and engine management, internal mixing and stratification, and direct injection strategies for affecting combustion stability. This work also examined spark-assisted Homogenous Charge Compression Ignition (HCCI) and exhaust after-treatment so as to extend the range and maximize the benefit of Homogenous Charge Compression Ignition (HCCI)/ Partially Premixed Compressionmore » Ignition (PPCI) operation. In summary the overall goals were; Investigate the fundamental processes that determine the practical boundaries of Low Temperature Combustion (LTC) engines; Develop methods to extend LTC boundaries to improve the fuel economy of HCCI engines fueled on gasoline and alternative blends, while operating with ultra low emissions; and Investigate alternate fuels, ignition and after-treatment for LTC and Partially Premixed compression Ignition (PPCI) engines.« less
  • The report describes the third year's efforts in a program to develop criteria for extending the applicability of low-emission, high-efficiency coal burners. For the small-scale fuel studies, 28 coals covering all ranks were tested under a wide variety of conditions to ascertain the impact of coal properties on the fate of fuel nitrogen (N). Significant accomplishments in this part of the program include: (1) bench-scale test results confirm the pilot-scale concept that decreasing the initial air/fuel ratio decreases fuel NOx formation; (2) detailed studies on optimizing a staged combustion system suggest that the stoichiometry producing minimum NOx emissions is amore » function of both fuel composition and primary-zone conditions; (3) distribution of the total fixed nitrogen (TFN) species--NO, NH/sub 3/, and HCN--leaving the first stage is strongly dependent on coal composition; (4) distribution of the first-stage fuel N emissions has a significant impact on second-stage exhaust NO emissions (minimum second-stage NO emissions depend on competition between first-stage NO and increased gas - and solid-phase N species); and (5) during staged combustion, increasing the rate of heat extraction from the first stage (fuel-rich zone) decreases the decay of TFN species, but dramatically decreases TFN conversion in the second stage (first-stage extraction reduces exhaust NO emissions).« less
  • The report summarizes technical progress during the fourth year of effort on EPA contract 68-02-2667. NOx and SOx emission characteristics of two low-NOx distributed-mixing burners were tested with three coals in a large water-tube simulator furnace (50-70 million Btu/hr firing rate). Increasing burner load, burner zone stoichiometry, or overall excess air increased NOx emissions. Staging was limited by increases in CO emissions and problems with flame stability at burner zone stoichiometries below 0.6. The feasibility of using dry sorbents injected directly into the furnace for SO/sub 2/ emission control was investigated. Sorbent type (Ca (OH)/sub 2/ vs. CaCO/sub 3/) andmore » injection location had a small effect on sulfur capture. Fuel sulfur content also affected sulfur capture. Sulfur captures on the order of 40-50 percent were obtained at Ca/S molar ratios of 2.0. Parametric studies of the sulfur capture process were performed in a specially constructed Boiler Simulator Furnace fired at 1.0 million Btu/hr. Under fuel-lean conditions, thermal history exerted controlling influence on sulfur capture. Firing and heat extraction rates strongly influenced sulfur capture due to their effect on thermal history. Sorbent location, burner zone stoichiometry, overall excess air, and tertiary air velocity had secondary effects on capture.« less
  • The report gives results of the first year's effort on this contract. Experimental studies were conducted at three scales to determine the influence of coal properties on NOx emissions. In addition, the use of sorbents to reduce SOx emissions from coal flames was investigated. Bench-scale (0.1 million Btu/hr) investigation concentrated on studies to define the effect of coal characteristics on fuel nitrogen conversion. Based on these investigations, the total coal nitrogen content does not appear to be the primary variable controlling fuel NO production in pulverized-coal flames. Experiments were conducted with research-design low-NOx burners at two scales (12.5 and 100more » million Btu/hr) using three coal types. Under optimum conditions, the NOx emissions, typically below 200 ppm (dry at 0% O/sub 2/), were only slightly dependent on coal characteristics. Preliminary investigations assessed the use of the low-NOx burner design to reduce NOx and SOx emissions by adding sorbents to the coal before the pulverizer. Limestone added this way gave 50, 70, and 80% reductions in SO/sub 2/ emissions at calcium/sulfur molar ratios of 1, 2, and 3, respectively.« less