SPICE analysis of signal propagation in Si microstrip detectors
- INFN, Padova (Italy). Sezione di Padova
- Univ. di Padova (Italy). Dipt. di Fisica
- Univ. di Cagliari (Italy). Istituto di Elettrotecnica
The main DC and AC characteristics of AC-coupled polysilicon-biased silicon microstrip detectors have been measured in order to determine the set of SPICE parameters of these devices based on a RC network. For this purpose each strip has been divided in 200 unit cells and simulations with 5 and 9 strips have been performed. The model is capable of calculating the interstrip and coupling impedance and phase angle in good agreement with experimental results up to a frequency of 1 MHz. The electrical propagation of a current signal simulating the charge pulse of an ionizing particle along the strips has been studied. The role of the input characteristics of the read-out electronics on the detector output signals has been addressed. The signal propagation has been studied also for anomalous working conditions of the detector, such as a strip with a break in the Al film, or disconnected from the read-out electronics.
- OSTI ID:
- 129168
- Report Number(s):
- CONF-941061-; ISSN 0018-9499; TRN: IM9550%%536
- Journal Information:
- IEEE Transactions on Nuclear Science, Vol. 42, Issue 4Pt1; Conference: Institute of Electrical and Electronic Engineers (IEEE) nuclear science symposium and medical imaging conference, Norfolk, VA (United States), 30 Oct - 5 Nov 1994; Other Information: PBD: Aug 1995