skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Characterization of Solids Deposited on the Modular Caustic-Side Solvent Extraction Unit (MCU) Strip Effluent (SE) Coalescer Media Removed in April 2015

Technical Report ·
DOI:https://doi.org/10.2172/1262319· OSTI ID:1262319
 [1]
  1. Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

On June 2015, Savannah River National Laboratory (SRNL) received a Strip Effluent (SE) coalescer (FLT-304) from MCU. That coalescer was first installed at MCU in late October 2014 and removed in April 2015. While processing approximately 48,700 gallons of strip solution, the pressure drop steadily increased linearly from 1 psi to near 16 psi (the administrative limit is 17 psi) with the total filtrate volume (2.1E-4 psi/gal of filtrate). The linear behavior is due to the combined effect of a constant deposition of material that starts from the closed-end to the mid-section of the coalescer reducing the available surface area of the coalescer for fluid passage (linearly with filtrate volume) and the formation of a secondary emulsion (water in NG-CSSX) on the fibers of the coalescer media. Both effects reduced the coalescer porosity by at least 13% (after processing 48,700 gallons). Before the coalescer was removed, it was flushed with a 10 mM boric acid solution to reduce the dose level. To determine the nature of the deposited material, a physical and chemical analysis of the coalescer was conducted. Characterization of this coalescer revealed the adsorption of organic containing amines (secondary amides and primary amines), TiDG, degraded modifier (with no hydroxyl group), MaxCalix, and oxidized hydrocarbon (possibly from Isopar™L or from lubricant used at MCU) onto the coalescer media. The amide and amines are possibly from the decomposition of the suppressor (TiDG). The modifier and MaxCalix were the largest components of the deposited organic material, as determined from leaching the coalescer with dichloromethane. Both the Fourier-Transformed Infrared (FTIR) and Fourier-Transformed Hydrogen Nuclear Magnetic Resonance (FT-HNMR) results indicated that some of the modifier was degraded (missing their OH groups). The modifier was observed everywhere in the examined coalescer pieces (FTIR), while the TiDG and its decomposition products were observed at the entrance discs of the coalescer. A solvent trim (a cocktail of solvent components with a high concentration of modifier) was added to the solvent on 2/22/2015. It is believed that the trim did not mix completely with the solvent and that it was subsequently spread around the MCU components including the coalescers, where it may have deposited. Chronologically, the modifier, the TiDG’s decomposition products and silicates deposited on the entrance discs first and after the pressure drop increased significantly, parts of the coalescer media detached itself from the central porous steel mandrel and a significant amount of steel debris, mercury, titanium, and additional aluminum and silicates deposited on the coalescer.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE Office of Environmental Management (EM)
DOE Contract Number:
DE-AC09-08SR22470
OSTI ID:
1262319
Report Number(s):
SRNL-STI-2016-00123; TRN: US1601599
Country of Publication:
United States
Language:
English