skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: System Study: Isolation Condenser 1998–2013

Abstract

This report presents an unreliability evaluation of the isolation condenser (ISO) system at four U.S. boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2013 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the ISO results.

Authors:
 [1]
  1. Idaho National Lab. (INL), Idaho Falls, ID (United States). Risk Assessment and Management Services Dept.
Publication Date:
Research Org.:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
Sponsoring Org.:
USDOE; US Nuclear Regulatory Commission (NRC)
OSTI Identifier:
1261718
Report Number(s):
INL/EXT-15-34437
TRN: US1601592
DOE Contract Number:  
AC07-05ID14517; NRC-HQ-14-D-0018
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; ISOLATION CONDENSERS; BWR TYPE REACTORS; DEMAND; EVALUATION; FAILURES; RELIABILITY; boiling water reactor; isolation condenser; operating experience; unreliability

Citation Formats

Schroeder, John Alton. System Study: Isolation Condenser 1998–2013. United States: N. p., 2015. Web. doi:10.2172/1261718.
Schroeder, John Alton. System Study: Isolation Condenser 1998–2013. United States. doi:10.2172/1261718.
Schroeder, John Alton. Sat . "System Study: Isolation Condenser 1998–2013". United States. doi:10.2172/1261718. https://www.osti.gov/servlets/purl/1261718.
@article{osti_1261718,
title = {System Study: Isolation Condenser 1998–2013},
author = {Schroeder, John Alton},
abstractNote = {This report presents an unreliability evaluation of the isolation condenser (ISO) system at four U.S. boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2013 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the ISO results.},
doi = {10.2172/1261718},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Sat Jan 31 00:00:00 EST 2015},
month = {Sat Jan 31 00:00:00 EST 2015}
}

Technical Report:

Save / Share: