Precise determination of the power transmission coefficient of low-loss passive linear two-ports by rf noise power and rf attenuation measurement techniques
Conference
·
OSTI ID:125878
- Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)
The paper presents the results of precision measurements of the power transmission coefficient of low-loss passive linear two-ports. Two different measurement approaches were intercompared, using RF noise power and RF attenuation measuring techniques. The noise power approach is preferably applied for the detection of small changes in attenuation.
- OSTI ID:
- 125878
- Report Number(s):
- CONF-940603-; TRN: 95:005769-0270
- Resource Relation:
- Conference: CPEM `94: conference on precision electromagnetic measurements, Boulder, CO (United States), 27 Jun - 1 Jul 1994; Other Information: PBD: 1994; Related Information: Is Part Of 1994 Conference on precision electromagnetic measurements digest; DeWeese, E.; Bennett, G. [eds.]; PB: 577 p.
- Country of Publication:
- United States
- Language:
- English
Similar Records
Noise equivalent circuit of linear passive two-ports with applications to transmission lines
Active and Passive RF Components for High-Power Systems
Technique for measuring the two-port scattering matrix of a plasma current drive antenna during high power operation
Journal Article
·
Tue Jun 01 00:00:00 EDT 1982
· IEEE Trans. Instrum. Meas.; (United States)
·
OSTI ID:125878
Active and Passive RF Components for High-Power Systems
Technical Report
·
Fri Sep 06 00:00:00 EDT 2002
·
OSTI ID:125878
Technique for measuring the two-port scattering matrix of a plasma current drive antenna during high power operation
Journal Article
·
Sat Feb 01 00:00:00 EST 1997
· Review of Scientific Instruments
·
OSTI ID:125878