Moore, R. L., and Cate, T. M. PERFORMANCE TEST OF A NORWOOD ELECTROSYN PRESSURE MEASURING SYSTEM.. United States: N. p., 1958.
Web. doi:10.2172/12536341.
Moore, R. L., & Cate, T. M. PERFORMANCE TEST OF A NORWOOD ELECTROSYN PRESSURE MEASURING SYSTEM.. United States. doi:10.2172/12536341.
Moore, R. L., and Cate, T. M. Tue .
"PERFORMANCE TEST OF A NORWOOD ELECTROSYN PRESSURE MEASURING SYSTEM.". United States.
doi:10.2172/12536341. https://www.osti.gov/servlets/purl/12536341.
@article{osti_12536341,
title = {PERFORMANCE TEST OF A NORWOOD ELECTROSYN PRESSURE MEASURING SYSTEM.},
author = {Moore, R. L. and Cate, T. M.},
abstractNote = {Performance tests of a Norwood Electrosyn Pressure Measuring System, having a transmitter with a span of 0 to 2500 psig and an environmental temperature rating of 200 degrees F maximum, indicate that an accuracy of + - 1.0% of span can be expected. The effects of changing environmental temperature, pressure cycling, and overranging were investigated. (author)},
doi = {10.2172/12536341},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Nov 11 00:00:00 EST 1958},
month = {Tue Nov 11 00:00:00 EST 1958}
}