skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Correlatons and Photon Statistsics in Nanocavity Emitters (invited).


Abstract not provided.

Publication Date:
Research Org.:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
Sponsoring Org.:
USDOE National Nuclear Security Administration (NNSA)
OSTI Identifier:
Report Number(s):
DOE Contract Number:
Resource Type:
Resource Relation:
Conference: Proposed for presentation at the Seminar at Physics Department, University of California Santa Barbara held January 29, 2015 in Santa Barbara, CA.
Country of Publication:
United States

Citation Formats

Chow, Weng W. Correlatons and Photon Statistsics in Nanocavity Emitters (invited).. United States: N. p., 2015. Web.
Chow, Weng W. Correlatons and Photon Statistsics in Nanocavity Emitters (invited).. United States.
Chow, Weng W. 2015. "Correlatons and Photon Statistsics in Nanocavity Emitters (invited).". United States. doi:.
title = {Correlatons and Photon Statistsics in Nanocavity Emitters (invited).},
author = {Chow, Weng W.},
abstractNote = {Abstract not provided.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = 2015,
month = 3

Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share:
  • The combination of certain solvent extraction separations and a special kind of liquid scintillation detector and electronics designed for alpha spectrometry allows some highly accurate, yet simple determinations of alpha-emitting nuclides. Counting efficiency is 99.68% with backgrounds of <0.02 cpm. Energy resolution and peak position are sufficient for the identification of many nuclides. Rejection of interference from ..beta.. and ..gamma.. radiation is >99.95%. The Photon/Electron Rejecting Alpha Liquid Scintillation (PERALS) equipment is described and procedures for the separation and determination of uranium, thorium, plutonium, polonium, radium, and trivalent actinides are outlined. 25 refs., 10 figs., 1 tab.
  • To overcome limitations of mechanical collimation in single photon imaging, a prototype electronically collimated gamma camera has been implemented by replacing the lead collimator with a unique 4x4 germanium detector. Coincident counts are recorded between the germanium detector and the uncollimated scintillation camera (Model Pho/gamma HP), stored in ''list'' mode and sorted as a function of position and energy within the germanium array. Each coincident count multiplexes activity on a conical surface through the object. As a first step to SPECT, demultiplexing is carried out to produce multiple-view pin-hole images of the object. In a new approach to demultiplexing, themore » planar distribution of coincident counts is mapped onto a spherical surface, thereby producing data which represent a convolution of the pin-hole projection with a circular point spread function on a spherical surface. Deconvolution is subsequently achieved either by iterative methods or a Fourier-filtering approach. Using these methods, pin-hole images have been obtained with point, line and uniformly distributed planar (8.8 cm diam) sources of Tc-99m, and a point source of Cs-137 (662 keV). The pin-hole image of a centrally located point source of Tc-99m produced a spatial resolution of 8.9 +- 1.2mm at a distance of 6cm from the germanium detector. Also, using the prototype system, the sensitivity of a 32x32 germanium detector based camera was deduced to be a factor of 70 higher than a conventionally collimated camera for imaging Tc-99m distributed in a 5cm diam cylinder at equivalent resolution. Thus, electronic collimation increases sensitivity, enables imaging at high energies and facilitates dynamic SPECT.« less
  • A prototype system has been used to measure the point spread function (PSF) and sensitivity characteristics of a germanium-scintillation camera (GSC) system for imaging single photon emitters. A detector consisting of two 5mm x 5mm x 6mm elements, fabricated on a single piece of high purity germanium, and a Pho/gamma HP scintillation camera were used. Experiments were conducted with a point source of Tc-99m to specify the threshold and energy resolution required in the germanium detector and to study the timing characteristics of coincidence detection.