skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Automated Advancements For Improved ISR.


Abstract not provided.

; ; ; ;
Publication Date:
Research Org.:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
Sponsoring Org.:
USDOE National Nuclear Security Administration (NNSA)
OSTI Identifier:
Report Number(s):
DOE Contract Number:
Resource Type:
Resource Relation:
Conference: Proposed for presentation at the Next-Generation Automated ISR Symposium held March 12-13, 2015 in Arlington, VA, US.
Country of Publication:
United States

Citation Formats

Hanselmann, Kathryn D., Czuchlewski, Kristina Rodriguez, Hudgens, James J., Castillo, Steven, and Vittitow, Michael P. Automated Advancements For Improved ISR.. United States: N. p., 2015. Web.
Hanselmann, Kathryn D., Czuchlewski, Kristina Rodriguez, Hudgens, James J., Castillo, Steven, & Vittitow, Michael P. Automated Advancements For Improved ISR.. United States.
Hanselmann, Kathryn D., Czuchlewski, Kristina Rodriguez, Hudgens, James J., Castillo, Steven, and Vittitow, Michael P. 2015. "Automated Advancements For Improved ISR.". United States. doi:.
title = {Automated Advancements For Improved ISR.},
author = {Hanselmann, Kathryn D. and Czuchlewski, Kristina Rodriguez and Hudgens, James J. and Castillo, Steven and Vittitow, Michael P.},
abstractNote = {Abstract not provided.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = 2015,
month = 3

Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share:
  • Abstract not provided.
  • Abstract not provided.
  • An improved automated electronic balance calibration and record system has been developed using a spread sheet to consolidate information required to calibrate electronic balances and satisfy requirements for traceability, validation and documentation. Several improvements have been made over an Epson HX-20{trademark} notebook computer-based balance calibration system, which was developed at the Savannah River Site in 1986 and used continuously since to annually calibrate electronic balances. These improvements included: built in tables of balance models performance test limits and calibration standards` apparent masses & uncertainties; calculated ratios of balance to test weight uncertainties; bar-code data input; enhanced graphs and tables; andmore » permanent electronic records. The software and hardware were thoroughly tested by calibrating 30 balances in another department. Hardware for importing data from balances through an RS-232 interface and bar code reader into a portable computer`s spread sheet was evaluated and found to add little value to the calibration process. Computerized data collection minimizes record handling and reduces paper work costs by >50%. Databases are established for each organization`s electronic balances that contain records for each balance that are identified by model, property identification number and location. In addition, each record contains calibration and expiration dates, performance testing information, etc. Details of equipment, statistical testing, spread sheet features and examples of the program are described.« less
  • This test utilizes submitochondrial particles (SMPs) to assay the effects of chemicals on oxidative phosphorylation enzymes normally present on mitochondrial membranes. The assay spectrophotometrically monitors the oxidation, or reduction, of nicotinamide adenine dinucleotide (NAD) in cuvettes containing chemicals and a reaction cocktail. The authors miniaturized the test into a 96-well microliter plate format and developed an automated monitoring system capable of repeated measurements of NAD(H) at frequent time intervals. This improved test system required less sample and reagents, allowed greater replication and was more efficient for assaying large numbers of samples. The 96-well microliter plates containing freeze-dried reactants performed wellmore » after storage for several months. Analyses of NAD(H) oxidation or reduction curves were used to develop dose-response relationships and calculate EC{sub 50} values for 1 8 chemicals. The miniaturized test EC{sub 50} values were predictive of known relationships between toxicity and chemical structure for various nitrated and chlorinated derivatives of benzene, phenol and aniline. In addition, the miniaturized test EC{sub 50} values correlated well with conventional SMPs EC{sub 50} values and LC{sub 50} values from invertebrate and fish acute toxicity bioassays. Preliminary testing showed promise for a variation of this miniaturized test system in which tetrazolium dyes were used as calorimetric indicators of chemical toxicity to electron transfer system (ETS) activity. These improvements increase the practicality of SMPs testing and may be used to produce 96-well test kits which are cost-effective, quick and accurate for screening the toxicity of chemicals, organic extracts and effluents.« less
  • Arch Mineral Corporation has an automated high wall miner called the Archveyor {trademark}. In production since 1992, it uses just two employees to operate the system. They consistently produce 91 metric tons per eight-hour employer-shift with peaks nearing 226 metric tons. The system uses a modified Joy 12CM miner cutting 3.7 meters. That loads into a 219 meter long continuous haulage Archveyor{trademark}. It discharges into a loadout vehicle that elevates the coal to load haul trucks. This technology can be adapted to mine over 305 meters into the high wall. Any continuous miner can be used to suit conditions. Itmore » is programmed to sump, shear down, sump, and shear up in a continuous cycle. It advances a set distance before the Archveyor{trademark} moves up behind it. The Archveyor{trademark} has a flight conveyor 838 mm wide used to tram and convey. Lift cylinders raise it off the ground to convey. To tram, the cylinders retract, dropping the Archveyor{trademark} to the ground. That places the full length of the return side or bottom of the flight conveyor in contract with the floor to tram in either direction. Programmable logic controllers are used with a gyroscope, gamma detectors, and inclinometers to keep on-heading and in-seam. Critical system functions are monitored and displayed for the operator. Safety, lower costs, and higher productivity drive the effort to use the Archveyor{trademark} technology underground. Arch Technology is assembling and preparing to install an underground system in the third quarter of 1996.« less