skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Air Sampling System Evaluation Template

Abstract

The ASSET1.0 software provides a template with which a user can evaluate an Air Sampling System against the latest version of ANSI N13.1 "Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities". The software uses the ANSI N13.1 PIC levels to establish basic design criteria for the existing or proposed sampling system. The software looks at such criteria as PIC level, type of radionuclide emissions, physical state of the radionuclide, nozzle entrance effects, particulate transmission effects, system and component accuracy and precision evaluations, and basic system operations to provide a detailed look at the subsystems of a monitoring and sampling system/program. A GAP evaluation can then be completed which leads to identification of design and operational flaws in the proposed systems. Corrective measures can then be limited to the GAPs.

Authors:
Publication Date:
Research Org.:
Westinghouse Savannah River Company
Sponsoring Org.:
USDOE
OSTI Identifier:
1230608
Report Number(s):
ASSET1.0; 001349IBMPC00
DOE Contract Number:  
P
Resource Type:
Software
Software Revision:
00
Software Package Number:
001349
Software Package Contents:
Media Directory; Software Abstract; Media Includes Source Code, Executable Modules; 1 CD Rom
Software CPU:
IBMPC
Open Source:
No
Source Code Available:
Yes
Country of Publication:
United States

Citation Formats

Blunt, Brent. Air Sampling System Evaluation Template. Computer software. Vers. 00. USDOE. 9 May. 2000. Web.
Blunt, Brent. (2000, May 9). Air Sampling System Evaluation Template (Version 00) [Computer software].
Blunt, Brent. Air Sampling System Evaluation Template. Computer software. Version 00. May 9, 2000.
@misc{osti_1230608,
title = {Air Sampling System Evaluation Template, Version 00},
author = {Blunt, Brent},
abstractNote = {The ASSET1.0 software provides a template with which a user can evaluate an Air Sampling System against the latest version of ANSI N13.1 "Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities". The software uses the ANSI N13.1 PIC levels to establish basic design criteria for the existing or proposed sampling system. The software looks at such criteria as PIC level, type of radionuclide emissions, physical state of the radionuclide, nozzle entrance effects, particulate transmission effects, system and component accuracy and precision evaluations, and basic system operations to provide a detailed look at the subsystems of a monitoring and sampling system/program. A GAP evaluation can then be completed which leads to identification of design and operational flaws in the proposed systems. Corrective measures can then be limited to the GAPs.},
doi = {},
year = {2000},
month = {5},
note =
}

Software: