Title: Monitoring of Double-Stud Wall Moisture Conditions in the Northeast

Abstract

Double-stud walls insulated with cellulose or low-density spray foam can have R-values of 40 or higher. However, double-stud walls have a higher risk of interior-sourced condensation moisture damage when compared with high-R approaches using exterior insulating sheathing. Moisture conditions in double-stud walls were monitored in Zone 5A (Massachusetts); three double-stud assemblies were compared.

Authors:
 [1]
  1. Building Science Corporation, Westford, MA (United States)
Publication Date:
Research Org.:
Building Science Corporation, Westford, MA (United States)
Sponsoring Org.:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B)
OSTI Identifier:
1220430
Report Number(s):
DOE/GO-102015-4589
7033
DOE Contract Number:
AC36-08GO28308
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
residential; Residential Buildings; BSC; Building Science Corporation; Building America; durability; moisture; moisture monitoring; double stud; high-R value; high-R walls; mold; cellulose; spray foam; open cell spray foam

Citation Formats

Ueno, K. Monitoring of Double-Stud Wall Moisture Conditions in the Northeast. United States: N. p., 2015. Web. doi:10.2172/1220430.
Ueno, K. Monitoring of Double-Stud Wall Moisture Conditions in the Northeast. United States. doi:10.2172/1220430.
Ueno, K. Sun . "Monitoring of Double-Stud Wall Moisture Conditions in the Northeast". United States. doi:10.2172/1220430. https://www.osti.gov/servlets/purl/1220430.
@article{osti_1220430,
title = {Monitoring of Double-Stud Wall Moisture Conditions in the Northeast},
author = {Ueno, K.},
abstractNote = {Double-stud walls insulated with cellulose or low-density spray foam can have R-values of 40 or higher. However, double-stud walls have a higher risk of interior-sourced condensation moisture damage when compared with high-R approaches using exterior insulating sheathing. Moisture conditions in double-stud walls were monitored in Zone 5A (Massachusetts); three double-stud assemblies were compared.},
doi = {10.2172/1220430},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Sun Mar 01 00:00:00 EST 2015},
month = {Sun Mar 01 00:00:00 EST 2015}
}

Technical Report:

Save / Share:
  • Double-stud walls insulated with cellulose or low-density spray foam can have R-values of 40 or higher. However, double stud walls have a higher risk of interior-sourced condensation moisture damage, when compared with high-R approaches using exterior insulating sheathing.; Moisture conditions in double stud walls were monitored in Zone 5A (Massachusetts); three double stud assemblies were compared.
  • Double-stud walls insulated with cellulose or low-density spray foam can have R-values of 40 or higher. However, double stud walls have a higher risk of interior-sourced condensation moisture damage, when compared with high-R approaches using exterior insulating sheathing. Moisture conditions in double stud walls were monitored in Zone 5A (Massachusetts); three double stud assemblies were compared.
  • Double stud walls have a higher risk of interior-sourced condensation moisture damage when compared with high-R approaches using exterior insulating sheathing. In this project, Building Science Corporation monitored moisture conditions in double-stud walls from 2011 through 2014 at a new production house located in Devens, Massachusetts. The builder, Transformations, Inc., has been using double-stud walls insulated with 12 in. of open cell polyurethane spray foam (ocSPF); however, the company has been considering a change to netted and blown cellulose insulation for cost reasons. Cellulose is a common choice for double-stud walls because of its lower cost (in most markets). However,more » cellulose is an air-permeable insulation, unlike spray foams, which increases interior moisture risks. The team compared three double-stud assemblies: 12 in. of ocSPF, 12 in. of cellulose, and 5-½ in. of ocSPF at the exterior of a double-stud wall (to approximate conventional 2 × 6 wall construction and insulation levels, acting as a control wall). These assemblies were repeated on the north and south orientations, for a total of six assemblies.« less
  • The focus of the study is on the performance of wall systems, and in particular, the moisture characteristics inside the wall cavity and in the wood sheathing. Furthermore, while this research will initially address new home construction, the goal is to address potential moisture issues in wall cavities of existing homes when insulation and air sealing improvements are made.
  • The focus of the study is on the performance of wall systems, and in particular, the moisture characteristics inside the wall cavity and in the wood sheathing. Furthermore, while this research will initially address new home construction, the goal is to address potential moisture issues in wall cavities of existing homes when insulation and air sealing improvements are made.