Title: Technology Solutions Case Study: Cold Climate Foundation Wall Hygrothermal Research Facility, Cloquet, Minnesota

Abstract

This case study describes the University of Minnesota’s Cloquet Residential Research Facility (CRRF) in northern Minnesota, which features more than 2,500 ft2 of below-grade space for building systems foundation hygrothermal research. Here, the NorthernSTAR Building America Partnership team researches ways to improve the energy efficiency of the building envelope, including wall assemblies, basements, roofs, insulation, and air leakage.

Publication Date:
Research Org.:
NorthernSTAR
Sponsoring Org.:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B) (Building America)
OSTI Identifier:
1220301
Report Number(s):
DOE/GO-102014-4441
6890
Country of Publication:
United States
Language:
English
Subject:
residential; Residential Buildings; NorthernSTAR; Building America; basement foundation insulation; WSP; building foundations; hygrothermal; thermal

Citation Formats

None. Technology Solutions Case Study: Cold Climate Foundation Wall Hygrothermal Research Facility, Cloquet, Minnesota. United States: N. p., 2014. Web.
None. Technology Solutions Case Study: Cold Climate Foundation Wall Hygrothermal Research Facility, Cloquet, Minnesota. United States.
None. Mon . "Technology Solutions Case Study: Cold Climate Foundation Wall Hygrothermal Research Facility, Cloquet, Minnesota". United States. doi:. https://www.osti.gov/servlets/purl/1220301.
@article{osti_1220301,
title = {Technology Solutions Case Study: Cold Climate Foundation Wall Hygrothermal Research Facility, Cloquet, Minnesota},
author = {None},
abstractNote = {This case study describes the University of Minnesota’s Cloquet Residential Research Facility (CRRF) in northern Minnesota, which features more than 2,500 ft2 of below-grade space for building systems foundation hygrothermal research. Here, the NorthernSTAR Building America Partnership team researches ways to improve the energy efficiency of the building envelope, including wall assemblies, basements, roofs, insulation, and air leakage.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Sep 01 00:00:00 EDT 2014},
month = {Mon Sep 01 00:00:00 EDT 2014}
}
  • This report focuses on the progress made to date and the technical details of the experiment. An overview of the experimental data being collected with some interesting highlights noted thus far is also provided. A full analysis of the experimental data and the drawing of conclusions with regard to the thermal and hygrothermal performance of the retrofit foundation insulation systems tested will only be possible after a full year of data has been collected in 2014.
  • Thermal and moisture problems in existing basements create a unique challenge as the exterior face of the wall is not easily or inexpensively accessible. This approach by the NorthernSTAR Building America Partnership team addresses thermal and moisture management from the interior face of the wall without disturbing the exterior soil and landscaping. It is effective at reducing energy loss through the wall principally during the heating season. The team conducted experiments at the Cloquet Residential Research Facility to test the heat and moisture performance of four hollow masonry block wall systems and two rim-joist systems. These systems were retrofitted withmore » interior insulation in compliance with the 2012 IECC. The research showed for the first time that, for masonry block walls in a cold climate, a solid bond beam or equivalent provides adequate resistance to moisture transport from a hollow core to the rim-joist cavity. Thus, a solid top course is a minimum requirement for an interior retrofit insulation system.« less
  • This project was funded jointly by the National Renewable Energy Laboratory (NREL) and Oak Ridge National Laboratory (ORNL). ORNL focused on developing a full basement wall system experimental database to enable others to validate hygrothermal simulation codes. NREL focused on testing the moisture durability of practical basement wall interior insulation retrofit solutions for cold climates. The project has produced a physically credible and reliable long-term hygrothermal performance database for retrofit foundation wall insulation systems in zone 6 and 7 climates that are fully compliant with the performance criteria in the 2009 Minnesota Energy Code. These data currently span the periodmore » from November 10, 2012 through May 31, 2014 and are anticipated to be extended through November 2014. The experimental data were configured into a standard format that can be published online and that is compatible with standard commercially available spreadsheet and database software.« less
  • Thermal and moisture problems in existing basements create a unique challenge because the exterior face of the wall is not easily or inexpensively accessible. This approach addresses thermal and moisture management from the interior face of the wall without disturbing the exterior soil and landscaping. the interior and exterior environments. This approach has the potential for improving durability, comfort, and indoor air quality. This project was funded jointly by the National Renewable Energy Laboratory (NREL) and Oak Ridge National Laboratory (ORNL). ORNL focused on developing a full basement wall system experimental database to enable others to validate hygrothermal simulation codes.more » NREL focused on testing the moisture durability of practical basement wall interior insulation retrofit solutions for cold climates. The project has produced a physically credible and reliable long-term hygrothermal performance database for retrofit foundation wall insulation systems in zone 6 and 7 climates that are fully compliant with the performance criteria in the 2009 Minnesota Energy Code. The experimental data were configured into a standard format that can be published online and that is compatible with standard commercially available spreadsheet and database software.« less