Title: Estimation of contamination volume at Seaway Area A, New York.

Abstract

The purpose of this analysis was to estimate the volume of soil with a radioactive contaminant activity level above the cleanup Guideline at Seaway Area A, Tonawanda, New York. A site-specific cleanup guideline of 40 pCi/g thorium-230 was derived for Seaway, as well as for the nearby Ashland 1 and Ashland 2 sites. All three are Formerly Utilized Sites Remedial Action Program (FUSRAP) properties. The level was developed to ensure protection of human health and the environment and compliance with applicable or relevant and appropriate requirements. The available data included historical discrete soil samples taken at the surface and at depth and results of a surficial gamma walkover with a sodium iodide (NaI) 2x2 sensor. The balance of this document provides background information about the site and discusses the available data sets, the methodology used, and the results and conclusions from the analysis.

Authors:
;
Publication Date:
Research Org.:
Argonne National Lab., IL (US)
Sponsoring Org.:
US Department of Energy (US)
OSTI Identifier:
12040
Report Number(s):
ANL/EAD/TM-86
TRN: AH200119%%242
DOE Contract Number:  
W-31109-ENG-38
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 4 Aug 1999
Country of Publication:
United States
Language:
English
Subject:
54 ENVIRONMENTAL SCIENCES; ACTIVITY LEVELS; COMPLIANCE; CONTAMINATION; NEW YORK; RECOMMENDATIONS; REMEDIAL ACTION; SODIUM IODIDES; SOILS; THORIUM 230

Citation Formats

Durham, L., and Johnson, R. Estimation of contamination volume at Seaway Area A, New York.. United States: N. p., 1999. Web. doi:10.2172/12040.
Durham, L., & Johnson, R. Estimation of contamination volume at Seaway Area A, New York.. United States. doi:10.2172/12040.
Durham, L., and Johnson, R. Wed . "Estimation of contamination volume at Seaway Area A, New York.". United States. doi:10.2172/12040. https://www.osti.gov/servlets/purl/12040.
@article{osti_12040,
title = {Estimation of contamination volume at Seaway Area A, New York.},
author = {Durham, L. and Johnson, R.},
abstractNote = {The purpose of this analysis was to estimate the volume of soil with a radioactive contaminant activity level above the cleanup Guideline at Seaway Area A, Tonawanda, New York. A site-specific cleanup guideline of 40 pCi/g thorium-230 was derived for Seaway, as well as for the nearby Ashland 1 and Ashland 2 sites. All three are Formerly Utilized Sites Remedial Action Program (FUSRAP) properties. The level was developed to ensure protection of human health and the environment and compliance with applicable or relevant and appropriate requirements. The available data included historical discrete soil samples taken at the surface and at depth and results of a surficial gamma walkover with a sodium iodide (NaI) 2x2 sensor. The balance of this document provides background information about the site and discusses the available data sets, the methodology used, and the results and conclusions from the analysis.},
doi = {10.2172/12040},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1999},
month = {8}
}