Title: Absorbed dose from 7-GeV bremsstrahlung in a PMMA phantom.

Abstract

Electron storage rings generate energetic bremsstrahlung photons through radiative interaction of the particle beam with the residual gas molecules and other components inside the storage ring. At the Advanced Photon Source (APS), where the stored beam energy is 7 GeV, bremsstrahlung generated in the straight sections of the insertion devices comes down through the beamlines. The resulting absorbed dose distributions by, this radiation in a 300 mm x 300 mm x 300 mm tissue substitute phantom were measured with LiF:Mg,Ti (TLD-700) thermoluminescent dosimeters. The average normalized absorbed dose, in a cross sectional area of 100 mm{sup 2} at a depth of 150 mm of the PMMA phantom, was measured as 3.3 x 10{sup 6} mGy h{sup {minus}1}W{sup {minus}1} for a 7-GeV bremsstrahhmg spectrum.

Authors:
; ;
Publication Date:
Research Org.:
Argonne National Lab., IL (US)
Sponsoring Org.:
US Department of Energy (US)
OSTI Identifier:
11923
Report Number(s):
ANL/XFD/CP-99726
TRN: US0102292
DOE Contract Number:  
W-31109-ENG-38
Resource Type:
Conference
Resource Relation:
Conference: 9th International Conference on Radiation Shielding, Tsukuba (JP), 10/17/1999--10/22/1999; Other Information: PBD: 4 Aug 1999
Country of Publication:
United States
Language:
English
Subject:
61 RADIATION PROTECTION AND DOSIMETRY; ADVANCED PHOTON SOURCE; BREMSSTRAHLUNG; THERMOLUMINESCENT DOSEMETERS; PARTICLE BEAMS; PHANTOMS; RADIATION DOSES; STORAGE RINGS; PMMA; TISSUE-EQUIVALENT MATERIALS

Citation Formats

Job, P. K., Pisharody, M., and Semones, E. Absorbed dose from 7-GeV bremsstrahlung in a PMMA phantom.. United States: N. p., 1999. Web.
Job, P. K., Pisharody, M., & Semones, E. Absorbed dose from 7-GeV bremsstrahlung in a PMMA phantom.. United States.
Job, P. K., Pisharody, M., and Semones, E. Wed . "Absorbed dose from 7-GeV bremsstrahlung in a PMMA phantom.". United States. https://www.osti.gov/servlets/purl/11923.
@article{osti_11923,
title = {Absorbed dose from 7-GeV bremsstrahlung in a PMMA phantom.},
author = {Job, P. K. and Pisharody, M. and Semones, E.},
abstractNote = {Electron storage rings generate energetic bremsstrahlung photons through radiative interaction of the particle beam with the residual gas molecules and other components inside the storage ring. At the Advanced Photon Source (APS), where the stored beam energy is 7 GeV, bremsstrahlung generated in the straight sections of the insertion devices comes down through the beamlines. The resulting absorbed dose distributions by, this radiation in a 300 mm x 300 mm x 300 mm tissue substitute phantom were measured with LiF:Mg,Ti (TLD-700) thermoluminescent dosimeters. The average normalized absorbed dose, in a cross sectional area of 100 mm{sup 2} at a depth of 150 mm of the PMMA phantom, was measured as 3.3 x 10{sup 6} mGy h{sup {minus}1}W{sup {minus}1} for a 7-GeV bremsstrahhmg spectrum.},