Title: First high temperature safety tests of AGR-1 TRISO fuel with the Fuel Accident Condition Simulator (FACS) furnace

Abstract

Three TRISO fuel compacts from the AGR-1 irradiation experiment were subjected to safety tests at 1600 and 1800 °C for approximately 300 h to evaluate the fission product retention characteristics. Silver behavior was dominated by rapid release of an appreciable fraction of the compact inventory (3–34%) at the beginning of the tests, believed to be from inventory residing in the compact matrix and outer pyrocarbon (OPyC) prior to the safety test. Measurable release of silver from intact particles appears to become apparent only after ~60 h at 1800 °C. The release rate for europium and strontium was nearly constant for 300 h at 1600 °C (reaching maximum values of approximately 2×10⁻³ and 8×10⁻⁴ respectively), and at this temperature the release may be mostly limited to inventory in the compact matrix and OPyC prior to the safety test. The release rate for both elements increased after approximately 120 h at 1800 °C, possibly indicating additional measurable release through the intact particle coatings. Cesium fractional release from particles with intact coatings was <10⁻⁶ after 300 h at 1600 °C or 100 h at 1800 °C, but release from the rare particles that experienced SiC failure during the test could be significant. However,more » Kr release was still very low for 300 h 1600 °C (<2 × 10⁻⁶). At 1800 °C, krypton release increased noticeably after SiC failure, reflecting transport through the intact outer pyrocarbon layer. Nonetheless, the krypton and cesium release fractions remained less than approximately 10⁻³ after 277 h at 1800 °C.« less

Authors:
 [1];  [1];  [1];  [1];  [1]
  1. Idaho National Lab. (INL), Idaho Falls, ID (United States)
Publication Date:
Research Org.:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
Sponsoring Org.:
USDOE Office of Nuclear Energy (NE)
OSTI Identifier:
1184722
Report Number(s):
INL/JOU-15-34344
Journal ID: ISSN 0022-3115; TRN: US1500205
DOE Contract Number:  
AC07-05ID14517
Resource Type:
Journal Article
Journal Name:
Journal of Nuclear Materials
Additional Journal Information:
Journal Volume: 464; Journal Issue: C; Journal ID: ISSN 0022-3115
Publisher:
Elsevier
Country of Publication:
United States
Language:
English
Subject:
11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; SILICON CARBIDES; CESIUM; KRYPTON; SILVER; TEMPERATURE RANGE 1000-4000 K; SAFETY; TESTING; EUROPIUM; PARTICLES; STRONTIUM; FISSION PRODUCTS; SIMULATORS; FAILURES; RELIABILITY; TRISO accident testing; coated particle fuel; FACS; irradiated fuel; safety testing

Citation Formats

Demkowicz, Paul A., Reber, Edward L., Scates, Dawn M., Scott, Les, and Collin, Blaise P. First high temperature safety tests of AGR-1 TRISO fuel with the Fuel Accident Condition Simulator (FACS) furnace. United States: N. p., 2015. Web. doi:10.1016/j.jnucmat.2015.05.006.
Demkowicz, Paul A., Reber, Edward L., Scates, Dawn M., Scott, Les, & Collin, Blaise P. First high temperature safety tests of AGR-1 TRISO fuel with the Fuel Accident Condition Simulator (FACS) furnace. United States. doi:10.1016/j.jnucmat.2015.05.006.
Demkowicz, Paul A., Reber, Edward L., Scates, Dawn M., Scott, Les, and Collin, Blaise P. Tue . "First high temperature safety tests of AGR-1 TRISO fuel with the Fuel Accident Condition Simulator (FACS) furnace". United States. doi:10.1016/j.jnucmat.2015.05.006.
@article{osti_1184722,
title = {First high temperature safety tests of AGR-1 TRISO fuel with the Fuel Accident Condition Simulator (FACS) furnace},
author = {Demkowicz, Paul A. and Reber, Edward L. and Scates, Dawn M. and Scott, Les and Collin, Blaise P.},
abstractNote = {Three TRISO fuel compacts from the AGR-1 irradiation experiment were subjected to safety tests at 1600 and 1800 °C for approximately 300 h to evaluate the fission product retention characteristics. Silver behavior was dominated by rapid release of an appreciable fraction of the compact inventory (3–34%) at the beginning of the tests, believed to be from inventory residing in the compact matrix and outer pyrocarbon (OPyC) prior to the safety test. Measurable release of silver from intact particles appears to become apparent only after ~60 h at 1800 °C. The release rate for europium and strontium was nearly constant for 300 h at 1600 °C (reaching maximum values of approximately 2×10⁻³ and 8×10⁻⁴ respectively), and at this temperature the release may be mostly limited to inventory in the compact matrix and OPyC prior to the safety test. The release rate for both elements increased after approximately 120 h at 1800 °C, possibly indicating additional measurable release through the intact particle coatings. Cesium fractional release from particles with intact coatings was <10⁻⁶ after 300 h at 1600 °C or 100 h at 1800 °C, but release from the rare particles that experienced SiC failure during the test could be significant. However, Kr release was still very low for 300 h 1600 °C (<2 × 10⁻⁶). At 1800 °C, krypton release increased noticeably after SiC failure, reflecting transport through the intact outer pyrocarbon layer. Nonetheless, the krypton and cesium release fractions remained less than approximately 10⁻³ after 277 h at 1800 °C.},
doi = {10.1016/j.jnucmat.2015.05.006},
journal = {Journal of Nuclear Materials},
issn = {0022-3115},
number = C,
volume = 464,
place = {United States},
year = {2015},
month = {9}
}