Abstract

This program set out to explore a scattering-based approach to concentrate sunlight with the aim of improving collector field reliability and of eliminating wind loading and gross mechanical movement through the use of a stationary collection optic. The approach is based on scattering sunlight from the focal point of a fixed collection optic into the confined modes of a sliding planar waveguide, where it is transported to stationary tubular heat transfer elements located at the edges. Optical design for the first stage of solar concentration, which entails focusing sunlight within a plane over a wide range of incidence angles (>120 degree full field of view) at fixed tilt, led to the development of a new, folded-path collection optic that dramatically out-performs the current state-of-the-art in scattering concentration. Rigorous optical simulation and experimental testing of this collection optic have validated its performance. In the course of this work, we also identified an opportunity for concentrating photovoltaics involving the use of high efficiency microcells made in collaboration with partners at the University of Illinois. This opportunity exploited the same collection optic design as used for the scattering solar thermal concentrator and was therefore pursued in parallel. This system was experimentally demonstrated tomore » achieve >200x optical concentration with >70% optical efficiency over a full day by tracking with <1 cm of lateral movement at fixed latitude tilt. The entire scattering concentrator waveguide optical system has been simulated, tested, and assembled at small scale to verify ray tracing models. These models were subsequently used to predict the full system optical performance at larger, deployment scale ranging up to >1 meter aperture width. Simulations at an aperture widths less than approximately 0.5 m with geometric gains ~100x predict an overall optical efficiency in the range 60-70% for angles up to 50 degrees from normal. However, the concentrator optical efficiency was found to decrease significantly with increasing aperture width beyond 0.5 m due to parasitic waveguide out-coupling loss and low-level absorption that become dominant at larger scale. A heat transfer model was subsequently implemented to predict collector fluid heat gain and outlet temperature as a function of flow rate using the optical model as a flux input. It was found that the aperture width size limitation imposed by the optical efficiency characteristics of the waveguide limits the absolute optical power delivered to the heat transfer element per unit length. As compared to state-of-the-art parabolic trough CPV system aperture widths approaching 5 m, this limitation leads to an approximate factor of order of magnitude increase in heat transfer tube length to achieve the same heat transfer fluid outlet temperature. The conclusion of this work is that scattering solar thermal concentration cannot be implemented at the scale and efficiency required to compete with the performance of current parabolic trough CSP systems. Applied within the alternate context of CPV, however, the results of this work have likely opened up a transformative new path that enables quasi-static, high efficiency CPV to be implemented on rooftops in the form factor of traditional fixed-panel photovoltaics.« less

Authors:
ORCiD logo [1]
  1. Pennsylvania State Univ., State College, PA (United States)
Publication Date:
Research Org.:
Pennsylvania State Univ., University Park, PA (United States)
Sponsoring Org.:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Solar Energy Technologies Office (EE-4S)
OSTI Identifier:
1182608
Report Number(s):
DOE-PSU-5798
DOE Contract Number:
EE0005798
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
14 SOLAR ENERGY; Solar concentration; microtracking; scattering; thermal; CSP; CPV

Citation Formats

Giebink, Noel C. Scattering Solar Thermal Concentrators. United States: N. p., 2015. Web. doi:10.2172/1182608.
Giebink, Noel C. Scattering Solar Thermal Concentrators. United States. doi:10.2172/1182608.
Giebink, Noel C. Sat . "Scattering Solar Thermal Concentrators". United States. doi:10.2172/1182608. https://www.osti.gov/servlets/purl/1182608.
@article{osti_1182608,
title = {Scattering Solar Thermal Concentrators},
author = {Giebink, Noel C.},
abstractNote = {This program set out to explore a scattering-based approach to concentrate sunlight with the aim of improving collector field reliability and of eliminating wind loading and gross mechanical movement through the use of a stationary collection optic. The approach is based on scattering sunlight from the focal point of a fixed collection optic into the confined modes of a sliding planar waveguide, where it is transported to stationary tubular heat transfer elements located at the edges. Optical design for the first stage of solar concentration, which entails focusing sunlight within a plane over a wide range of incidence angles (>120 degree full field of view) at fixed tilt, led to the development of a new, folded-path collection optic that dramatically out-performs the current state-of-the-art in scattering concentration. Rigorous optical simulation and experimental testing of this collection optic have validated its performance. In the course of this work, we also identified an opportunity for concentrating photovoltaics involving the use of high efficiency microcells made in collaboration with partners at the University of Illinois. This opportunity exploited the same collection optic design as used for the scattering solar thermal concentrator and was therefore pursued in parallel. This system was experimentally demonstrated to achieve >200x optical concentration with >70% optical efficiency over a full day by tracking with <1 cm of lateral movement at fixed latitude tilt. The entire scattering concentrator waveguide optical system has been simulated, tested, and assembled at small scale to verify ray tracing models. These models were subsequently used to predict the full system optical performance at larger, deployment scale ranging up to >1 meter aperture width. Simulations at an aperture widths less than approximately 0.5 m with geometric gains ~100x predict an overall optical efficiency in the range 60-70% for angles up to 50 degrees from normal. However, the concentrator optical efficiency was found to decrease significantly with increasing aperture width beyond 0.5 m due to parasitic waveguide out-coupling loss and low-level absorption that become dominant at larger scale. A heat transfer model was subsequently implemented to predict collector fluid heat gain and outlet temperature as a function of flow rate using the optical model as a flux input. It was found that the aperture width size limitation imposed by the optical efficiency characteristics of the waveguide limits the absolute optical power delivered to the heat transfer element per unit length. As compared to state-of-the-art parabolic trough CPV system aperture widths approaching 5 m, this limitation leads to an approximate factor of order of magnitude increase in heat transfer tube length to achieve the same heat transfer fluid outlet temperature. The conclusion of this work is that scattering solar thermal concentration cannot be implemented at the scale and efficiency required to compete with the performance of current parabolic trough CSP systems. Applied within the alternate context of CPV, however, the results of this work have likely opened up a transformative new path that enables quasi-static, high efficiency CPV to be implemented on rooftops in the form factor of traditional fixed-panel photovoltaics.},
doi = {10.2172/1182608},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Sat Jan 31 00:00:00 EST 2015},
month = {Sat Jan 31 00:00:00 EST 2015}
}

Technical Report:

Save / Share:
  • Pennsylvania State University is one of the 2012 SunShot CSP R&D awardee for their advanced collectors. This fact sheet explains the motivation, description, and impact of the project.
  • This is a report on Holographic Concentrators for Solar Thermal Rocket Engines. The object of the work was to demonstrate that highly reflective holograms could be used as solar concentrators to heat liquid hydrogen for use as a propellant in satellite boost engines. The interest in this results from the need for a reliable, inexpensive alternate for conventional rockets.
  • A small experimental solar collector test facility has been established on the campus of the University of Chicago. This capability has been used to explore applications of nonimaging optics for solar thermal concentration in three substantially different configurations: (1) a single stage system with moderate concentration on an evacuated absorber (a 5.25X evacuated tube Compound Parabolic Concentrator or CPC), (2) a two stage system with high concentration and a non-evacuated absorber (a 16X Fresnel lens/CPC type mirror) and (3) moderate concentration single stage systems with non-evacuated absorbers for lower temperature (a 3X and a 6.5X CPC). Prototypes of each ofmore » these systems have been designed, built and tested. The performance characteristics are presented. In addition a 73 m/sup 2/ experimental array of 3X non-evacuated CPC's has been installed in a school heating system on the Navajo Indian Reservation in New Mexico. The full array has a peak noon time efficiency of approx. 50% at ..delta..T = 50/sup 0/C above ambient and has supplied about half the school's heat load for the past two heating seasons. Several theoretical features of nonimaging concentration have been investigated including their long term energy collecting behavior. The measured performance of the different systems shows clearly that non-tracking concentrators can provide solar thermal energy from moderately high low temperature regimes (> 50/sup 0/C above ambient) up into the mid-temperature region (well above 200/sup 0/C above ambient). The measured efficiency at 220/sup 0/C for the 5.25X CPC was as high or higher than that for any of the commercial tracking systems tested.« less
  • The major mechanical design and cost differences between concentrator subsystems are identified. Parabolic dishes and troughs are designed to the same specifications as heliostats, using the same glass mirror/steel structure design concept and their costs are estimated on a consistent, comparable basis, using the heliostat cost data base. The results show inherent cost differences arising from differences in geometry, the cost of providing curvature and wind loadings. The estimated cost increases, relative to heliostats, are 15% to 50% for dishes and 0% to 30% for troughs, considering the combined effect of several analysis uncertainties.
  • Work on the development of Compound Parabolic Concentrators (CPC) is described. A tenfold concentrator with a cavity receiver was constructed and tested. The optical efficiency was very good (65 percent), but the thermal performance was degraded by heat losses of the cavity receiver. A 20 ft/sup 2/ (1.86 m/sup 2/) concentrating collector (5.3x) has been tested for thermal and optical performance, and the optical efficiency was excellent (68 percent). In this collector, aluminum extrusions were used to define the CPC shape and provide the fluid-flow path. A 30 ft (9.14 m) long collector (10x) has been designed and is beingmore » built for daily-cycle testing. The expected performance of this collector has been evaluated. The conceptual design of a lightweight collector using evacuated glass tubes around the absorber is presented. Various construction techniques for use with low-cost materials, such as plastics, are being evaluated for this collector. Optical design studies of Compound Parabolic Concentrators for tubular absorbers and for use as secondary concentrators are discussed. Comparison of the CPC with tube and the CPC with one-sided flat absorber shows that the tubular configuration is preferable not only because of lower heat losses but also because of lower collector cost. For tracking concentrators with line focus, the use of second-stage concentrators is found to be cost effective; the CPC is found to be significantly better for this application than a V-trough. A summary of the results of subcontracts described in the previous progress report are presented, and the influence of these results on ANL programs is noted.« less