skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Coupling impedance of an in-vacuum undulator: Measurement, simulation, and analytical estimation

Authors:
; ; ; ;
Publication Date:
Sponsoring Org.:
USDOE
OSTI Identifier:
1180979
Grant/Contract Number:
AC02-98CH10886
Resource Type:
Journal Article: Published Article
Journal Name:
Physical Review Special Topics - Accelerators and Beams
Additional Journal Information:
Journal Volume: 17; Journal Issue: 7; Journal ID: ISSN 1098-4402
Publisher:
American Physical Society
Country of Publication:
United States
Language:
English

Citation Formats

Smaluk, Victor, Fielder, Richard, Blednykh, Alexei, Rehm, Guenther, and Bartolini, Riccardo. Coupling impedance of an in-vacuum undulator: Measurement, simulation, and analytical estimation. United States: N. p., 2014. Web. doi:10.1103/PhysRevSTAB.17.074402.
Smaluk, Victor, Fielder, Richard, Blednykh, Alexei, Rehm, Guenther, & Bartolini, Riccardo. Coupling impedance of an in-vacuum undulator: Measurement, simulation, and analytical estimation. United States. doi:10.1103/PhysRevSTAB.17.074402.
Smaluk, Victor, Fielder, Richard, Blednykh, Alexei, Rehm, Guenther, and Bartolini, Riccardo. Fri . "Coupling impedance of an in-vacuum undulator: Measurement, simulation, and analytical estimation". United States. doi:10.1103/PhysRevSTAB.17.074402.
@article{osti_1180979,
title = {Coupling impedance of an in-vacuum undulator: Measurement, simulation, and analytical estimation},
author = {Smaluk, Victor and Fielder, Richard and Blednykh, Alexei and Rehm, Guenther and Bartolini, Riccardo},
abstractNote = {},
doi = {10.1103/PhysRevSTAB.17.074402},
journal = {Physical Review Special Topics - Accelerators and Beams},
number = 7,
volume = 17,
place = {United States},
year = {Fri Jul 25 00:00:00 EDT 2014},
month = {Fri Jul 25 00:00:00 EDT 2014}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record at 10.1103/PhysRevSTAB.17.074402

Citation Metrics:
Cited by: 2works
Citation information provided by
Web of Science

Save / Share:
  • One of the important issues of the in-vacuum undulator design is the coupling impedance of the vacuum chamber, which includes tapered transitions with variable gap size. In order to get complete and reliable information on the impedance, analytical estimate, numerical simulations and beam-based measurements have been performed at Diamond Light Source, a forthcoming upgrade of which includes introducing additional insertion device (ID) straights. Moreover, the impedance of an already existing ID vessel geometrically similar to the new one has been measured using the orbit bump method. The measurement results in comparison with analytical estimations and numerical simulations are discussed inmore » this paper.« less
  • No abstract prepared.
  • A method is presented for calculating the real part of the longitudinal impedance {ital Z} at a frequency {omega} for both a small hole and a long slot in a beam vacuum chamber with a circular cross section. The length of the slot can be arbitrarily large; the only requirement of the dimensions of the slots is that its width be much smaller than {ital c}/{omega}. Regular arrays of {ital N} slots periodically distributed along the pipe are also considered. The equation relating the real part of the impedance to the energy radiated by the slot into waveguide eigenmodes ismore » the basis of this method. We show that in addition to broadband impedance, there are narrow peaks in Re{ital Z}. For a single slot, the peaks are located slightly above the cutoff frequencies of various waveguide modes. For a periodic array, additional peaks are generated at frequencies determined by the array period. These peaks can be partially suppressed by randomization of the positions of the slots.« less
  • This study evaluated a new technology of bioelectrical-impedance (BI) measurement that makes use of multiple frequencies (5, 50, and 100 kHz) for estimation of extracellular and total body water. In 36 healthy males, resistance and reactance at three frequencies were compared with extra-cellular water (ECW) and total body water (TBW) determined by isotope dilution. ECW was best predicted by resistance measured at 5 kHz, corrected for height and weight (R = 0.930, SEE = 1.94 L) whereas TBW was best predicted by resistance at 100 kHZ and weight (R = 0.947, SEE = 2.64 L). Cross-validation analysis on two randomlymore » selected subsets (n = 18 each) indicated that the prediction equations were reproducible and valid. Thus, BI at dual frequencies is valid for determination of body-water compartments and may be useful in the nutritional assessment of patients in whom body water and hydration is of clinical concern.« less