skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Ti Hemi boombox experiment

Abstract

Previous deformation experiments in which IR imaging was used pointed to a correlation in between IR signature in areas where heat was expected to be. The surface is not uniform during deformation experiments which cause cracks in the image in areas with increased temperature. To measure temperature under dynamic conditions, simultaneous reflectivity and radiance measurement under events of interest is needed. To measure a temperature measurement, a Reflectance measurement taken by framing camera at the edge of the camera sensitivity (700nm). Allows relative measurement at this wavelength. At reasonable temperatures the spectral radiance should peak near 2u and be 3-4 orders of magnitude higher than at 700 nm.

Authors:
 [1];  [1]
  1. Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
Publication Date:
Research Org.:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1179848
Report Number(s):
LA-UR-15-23660
DOE Contract Number:  
AC52-06NA25396
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
36 MATERIALS SCIENCE; 42 ENGINEERING; 71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS

Citation Formats

Miller, Phillip Isaac, and Hull, Lawrence Mark. Ti Hemi boombox experiment. United States: N. p., 2015. Web. doi:10.2172/1179848.
Miller, Phillip Isaac, & Hull, Lawrence Mark. Ti Hemi boombox experiment. United States. doi:10.2172/1179848.
Miller, Phillip Isaac, and Hull, Lawrence Mark. Thu . "Ti Hemi boombox experiment". United States. doi:10.2172/1179848. https://www.osti.gov/servlets/purl/1179848.
@article{osti_1179848,
title = {Ti Hemi boombox experiment},
author = {Miller, Phillip Isaac and Hull, Lawrence Mark},
abstractNote = {Previous deformation experiments in which IR imaging was used pointed to a correlation in between IR signature in areas where heat was expected to be. The surface is not uniform during deformation experiments which cause cracks in the image in areas with increased temperature. To measure temperature under dynamic conditions, simultaneous reflectivity and radiance measurement under events of interest is needed. To measure a temperature measurement, a Reflectance measurement taken by framing camera at the edge of the camera sensitivity (700nm). Allows relative measurement at this wavelength. At reasonable temperatures the spectral radiance should peak near 2u and be 3-4 orders of magnitude higher than at 700 nm.},
doi = {10.2172/1179848},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2015},
month = {5}
}

Technical Report:

Save / Share: