Title: Coded Aperture Imaging for Fluorescent X-rays-Biomedical Applications

Abstract

Employing a coded aperture pattern in front of a charge couple device pixilated detector (CCD) allows for imaging of fluorescent x-rays (6-25KeV) being emitted from samples irradiated with x-rays. Coded apertures encode the angular direction of x-rays and allow for a large Numerical Aperture x- ray imaging system. The algorithm to develop the self-supported coded aperture pattern of the Non Two Holes Touching (NTHT) pattern was developed. The algorithms to reconstruct the x-ray image from the encoded pattern recorded were developed by means of modeling and confirmed by experiments. Samples were irradiated by monochromatic synchrotron x-ray radiation, and fluorescent x-rays from several different test metal samples were imaged through the newly developed coded aperture imaging system. By choice of the exciting energy the different metals were speciated.

Authors:
; ; ;
Publication Date:
Research Org.:
Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
Sponsoring Org.:
USDOE Office of Science (SC)
OSTI Identifier:
1171122
Report Number(s):
LBNL-6304E
DOE Contract Number:  
DE-AC02-05CH11231
Resource Type:
Conference
Resource Relation:
Conference: Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, Granlibakken, Lake Tahoe, June 16 to June 21, 2013
Country of Publication:
United States
Language:
English
Subject:
59 BASIC BIOLOGICAL SCIENCES; 46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 47 OTHER INSTRUMENTATION; 07 ISOTOPE AND RADIATION SOURCES; Coded aperture, NTHT, Fluorescent x-rays

Citation Formats

Haboub, Abdel, MacDowell, Alastair, Marchesini, Stefano, and Parkinson, Dilworth. Coded Aperture Imaging for Fluorescent X-rays-Biomedical Applications. United States: N. p., 2013. Web.
Haboub, Abdel, MacDowell, Alastair, Marchesini, Stefano, & Parkinson, Dilworth. Coded Aperture Imaging for Fluorescent X-rays-Biomedical Applications. United States.
Haboub, Abdel, MacDowell, Alastair, Marchesini, Stefano, and Parkinson, Dilworth. Sat . "Coded Aperture Imaging for Fluorescent X-rays-Biomedical Applications". United States. https://www.osti.gov/servlets/purl/1171122.
@article{osti_1171122,
title = {Coded Aperture Imaging for Fluorescent X-rays-Biomedical Applications},
author = {Haboub, Abdel and MacDowell, Alastair and Marchesini, Stefano and Parkinson, Dilworth},
abstractNote = {Employing a coded aperture pattern in front of a charge couple device pixilated detector (CCD) allows for imaging of fluorescent x-rays (6-25KeV) being emitted from samples irradiated with x-rays. Coded apertures encode the angular direction of x-rays and allow for a large Numerical Aperture x- ray imaging system. The algorithm to develop the self-supported coded aperture pattern of the Non Two Holes Touching (NTHT) pattern was developed. The algorithms to reconstruct the x-ray image from the encoded pattern recorded were developed by means of modeling and confirmed by experiments. Samples were irradiated by monochromatic synchrotron x-ray radiation, and fluorescent x-rays from several different test metal samples were imaged through the newly developed coded aperture imaging system. By choice of the exciting energy the different metals were speciated.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2013},
month = {6}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: