skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: VHDL CONTROL ROUTER. VHDL Control Routing Simulator

Abstract

The control router simulates a backplane consisting of up to 16 slot. Slot 0, reserved for a control module (cr-ctrl), generates the system clocks and provides the serial interface to the Gating Logic. The remaining 15 slots (1-15) contain routing modules (cr mod), each having up to 64 serial inputs and outputs with FIFOs. Messages to be transmitted to the Control Router are taken from text files. There are currently 17 such source files. In the model, the serial output of each source is connected to multiple receivers, so that there are 8 identical messages transmitted to the router for each message file entry.

Authors:
 [1]
  1. Fermi Accelerator Lab., Batavia, IL (United States)
Publication Date:
Research Org.:
Fermi National Accelerator Lab., Batavia, IL (United States)
Sponsoring Org.:
USDOE Office of Energy Research, Washington, DC (United States)
OSTI Identifier:
115673
Report Number(s):
ESTSC-001037MLTPL00
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 1 Mar 1994
Country of Publication:
United States
Language:
English
Subject:
99 MATHEMATICS, COMPUTERS, INFORMATION SCIENCE, MANAGEMENT, LAW, MISCELLANEOUS; 42 ENGINEERING NOT INCLUDED IN OTHER CATEGORIES; V CODES; COMPUTERIZED CONTROL SYSTEMS; COMPUTER PROGRAM DOCUMENTATION; EQUIPMENT INTERFACES

Citation Formats

Venard, J. VHDL CONTROL ROUTER. VHDL Control Routing Simulator. United States: N. p., 1994. Web.
Venard, J. VHDL CONTROL ROUTER. VHDL Control Routing Simulator. United States.
Venard, J. Tue . "VHDL CONTROL ROUTER. VHDL Control Routing Simulator". United States.
@article{osti_115673,
title = {VHDL CONTROL ROUTER. VHDL Control Routing Simulator},
author = {Venard, J.},
abstractNote = {The control router simulates a backplane consisting of up to 16 slot. Slot 0, reserved for a control module (cr-ctrl), generates the system clocks and provides the serial interface to the Gating Logic. The remaining 15 slots (1-15) contain routing modules (cr mod), each having up to 64 serial inputs and outputs with FIFOs. Messages to be transmitted to the Control Router are taken from text files. There are currently 17 such source files. In the model, the serial output of each source is connected to multiple receivers, so that there are 8 identical messages transmitted to the router for each message file entry.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1994},
month = {3}
}

Technical Report:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that may hold this item. Keep in mind that many technical reports are not cataloged in WorldCat.

Save / Share: