Title: Hanford Single-Shell Tank Leak Causes and Locations - 241-BY and 241-TY Farm

Abstract

This document identifies 241-BY Tank Farm (BY Farm) and 241-TY Tank Farm (TY Farm) lead causes and locations for the 100 series leaking tanks (241-BY-103, 241-TY-103, 241-TY-104, 241-TY-105 and 241-TY-106) identified in RPP-RPT-43704, Hanford BY Farm Leak Assessments Report, and in RPP-RPT-42296, Hanford TY Farm Leak Assessments Report. This document satisfies the BY and TY Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

Authors:
;
Publication Date:
Research Org.:
Hanford Site (HNF), Richland, WA (United States)
Sponsoring Org.:
USDOE Office of Environmental Management (EM)
Contributing Org.:
Washington River Protection Solutions
OSTI Identifier:
1154954
Report Number(s):
RPP-RPT-54911 Rev. 1
M-045-91F; T04; RPP-RPT-42296; RPP-RPT-43704
DOE Contract Number:  
DE-AC27-08RV14800
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English

Citation Formats

Girardot, Crystal L., and Harlow, Donald G.. Hanford Single-Shell Tank Leak Causes and Locations - 241-BY and 241-TY Farm. United States: N. p., 2014. Web. doi:10.2172/1154954.
Girardot, Crystal L., & Harlow, Donald G.. Hanford Single-Shell Tank Leak Causes and Locations - 241-BY and 241-TY Farm. United States. doi:10.2172/1154954.
Girardot, Crystal L., and Harlow, Donald G.. Thu . "Hanford Single-Shell Tank Leak Causes and Locations - 241-BY and 241-TY Farm". United States. doi:10.2172/1154954. https://www.osti.gov/servlets/purl/1154954.
@article{osti_1154954,
title = {Hanford Single-Shell Tank Leak Causes and Locations - 241-BY and 241-TY Farm},
author = {Girardot, Crystal L. and Harlow, Donald G.},
abstractNote = {This document identifies 241-BY Tank Farm (BY Farm) and 241-TY Tank Farm (TY Farm) lead causes and locations for the 100 series leaking tanks (241-BY-103, 241-TY-103, 241-TY-104, 241-TY-105 and 241-TY-106) identified in RPP-RPT-43704, Hanford BY Farm Leak Assessments Report, and in RPP-RPT-42296, Hanford TY Farm Leak Assessments Report. This document satisfies the BY and TY Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.},
doi = {10.2172/1154954},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Sep 04 00:00:00 EDT 2014},