Title: Demonstration of Advanced Technologies for Multi-Load Washers in Hospitality and Healthcare -- Ozone Based Laundry Systems

Technical Report ·
DOI:https://doi.org/10.2172/1151875· OSTI ID:1151875
 [1];  [1];  [1];  [2];  [3];  [3];  [3]
  1. Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
  2. Efficiency Solutions, LLC (United States)
  3. Navigant Consulting, Inc. (United States)

The objective of this demonstration project was to evaluate market-ready retrofit technologies for reducing the energy and water use of multi-load washers in healthcare and hospitality facilities. Specifically, this project evaluated laundry wastewater recycling technology in the hospitality sector and ozone laundry technology in both the healthcare and hospitality sectors. This report documents the demonstration of ozone laundry system installations at the Charleston Place Hotel in Charleston, South Carolina, and the Rogerson House assisted living facility in Boston, Massachusetts.

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
1151875
Report Number(s):
PNNL-23536; BT0201000
Country of Publication:
United States
Language:
English