skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: I/O Coordination to Improve HEC System Performance: A Marriage of Analytical Modeling, Control Theory, and Differentiated I/O Performance

Authors:
 [1];
  1. UTEP
Publication Date:
Research Org.:
The University of Texas at El Paso (UTEP)
Sponsoring Org.:
USDOE Office of Science (SC)
OSTI Identifier:
1122130
Report Number(s):
DOE-UTEP-0001768
DOE Contract Number:
SC0001768
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
97 MATHEMATICS AND COMPUTING

Citation Formats

Teller, Patricia Jane, and Arunagiri, Sarala. I/O Coordination to Improve HEC System Performance: A Marriage of Analytical Modeling, Control Theory, and Differentiated I/O Performance. United States: N. p., 2014. Web. doi:10.2172/1122130.
Teller, Patricia Jane, & Arunagiri, Sarala. I/O Coordination to Improve HEC System Performance: A Marriage of Analytical Modeling, Control Theory, and Differentiated I/O Performance. United States. doi:10.2172/1122130.
Teller, Patricia Jane, and Arunagiri, Sarala. Wed . "I/O Coordination to Improve HEC System Performance: A Marriage of Analytical Modeling, Control Theory, and Differentiated I/O Performance". United States. doi:10.2172/1122130. https://www.osti.gov/servlets/purl/1122130.
@article{osti_1122130,
title = {I/O Coordination to Improve HEC System Performance: A Marriage of Analytical Modeling, Control Theory, and Differentiated I/O Performance},
author = {Teller, Patricia Jane and Arunagiri, Sarala},
abstractNote = {},
doi = {10.2172/1122130},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Mar 05 00:00:00 EST 2014},
month = {Wed Mar 05 00:00:00 EST 2014}
}

Technical Report:

Save / Share:
  • This report documents the current status of the modeling, control design, and embedded control research for the magnetic bearing canned rotor pump being used as a demonstration platform for deeply integrating instrumentation and controls (I{\&}C) into nuclear power plant components. This pump is a highly inter-connected thermo/electro/mechanical system that requires an active control system to operate. Magnetic bearings are inherently unstable system and without active, moment by moment control, the rotor would contact fixed surfaces in the pump causing physical damage. This report details the modeling of the pump rotordynamics, fluid forces, electromagnetic properties of the protective cans, active magneticmore » bearings, power electronics, and interactions between different dynamical models. The system stability of the unforced and controlled rotor are investigated analytically. Additionally, controllers are designed using proportional derivative (PD) control, proportional integral derivative (PID) control, voltage control, and linear quadratic regulator (LQR) control. Finally, a design optimization problem that joins the electrical, mechanical, magnetic, and control system design into one problem to balance the opposing needs of various design criteria using the embedded system approach is presented.« less
  • This training document was written to assist users of computer program HEC-5, Simulation of Flood Control and Conservation Systems, in water-quality applications. This document supplements the program Users Manual, which is the basic documentation for the program. In addition to a brief description of the water-quality version of the HEC-5 model, this document also includes descriptions of application procedure, data requirements, and example program input and output.
  • Test results from a high-pressure electronically controlled fuel injection system are compared with a commercial mechanical injection system on a single cylinder, diesel test engine using an inlet boost pressue ratio of 2.6:1. The electronic fuel injection system achieved high pressure by means of a fluid intensifier with peak injection pressures of 47 to 69 MPa. Reduced exhaust emissions were demonstrated with an increasing rate of injection followed by a fast cutoff of injection. The reduction in emissions is more responsive to the rate of injection and injection timing than to high peak injection pressure.
  • The pilot signal parameter optimization and power transponder analyses are presented. The SPS antenna phase control system is modeled and the hardware simulation study described. Ionospheric and system phase error effects and the effects of high power amplifier phase and amplitude jitters are considered. Parameter optimization of the spread spectrum receiver, consisting of the carrier tracking loop and the code tracking loop, is described.
  • This research effort is a part of the Light-Water Reactor Sustainability (LWRS) Program, which is a research and development (R&D) program sponsored by Department of Energy (DOE) and performed in close collaboration with industry R&D programs that provides the technical foundations for licensing and managing the long-term, safe, and economical operation of current nuclear power plants. The LWRS program serves to help the U.S. nuclear industry adopt new technologies and engineering solutions that facilitate the continued safe operation of the plants and extension of the current operating licenses. The long term viability of existing nuclear power plants in the U.S.more » will depend upon maintaining high capacity factors, avoiding nuclear safety issues and reducing operating costs. The slow progress in the construction on new nuclear power plants has placed in increased importance on maintaining the output of the current fleet of nuclear power plants. Recently expanded natural gas production has placed increased economic pressure on nuclear power plants due to lower cost competition. Until recently, power uprate projects had steadily increased the total output of the U.S. nuclear fleet. Errors made during power plant upgrade projects have now removed three nuclear power plants from the U.S. fleet and economic considerations have caused the permanent shutdown of a fourth plant. Additionally, several utilities have cancelled power uprate projects citing economic concerns. For the past several years net electrical generation from U.S. nuclear power plants has been declining. One of few remaining areas where significant improvements in plant capacity factors can be made is in minimizing the duration of refueling outages. Managing nuclear power plant outages is a complex and difficult task. Due to the large number of complex tasks and the uncertainty that accompanies them, outage durations routinely exceed the planned duration. The ability to complete an outage on or near schedule depends upon the performance of the outage management organization. During an outage, the outage control center (OCC) is the temporary command center for outage managers and provides several critical functions for the successful execution of the outage schedule. Essentially, the OCC functions to facilitate information inflow, assist outage management in processing information and to facilitate the dissemination of information to stakeholders. Currently, outage management activities primarily rely on telephone communication, face to face reports of status and periodic briefings in the OCC. Much of the information displayed in OCCs is static and out of date requiring an evaluation to determine if it is still valid. Several advanced communication and collaboration technologies have shown promise for facilitating the information flow into, across and out of the OCC. Additionally, advances in the areas of mobile worker technologies, computer based procedures and electronic work packages can be leveraged to improve the availability of real time status to outage managers.« less