Title: Improved Estimates of Fault Dose Exterior to the PHENIX South Side Shield Configuration

Abstract

This note presents the results of more detailed calculations intended to estimate the distance away from the shield wall where high occupancy would be permissible.

Authors:
 [1]
  1. Brookhaven National Lab. (BNL), Upton, NY (United States)
Publication Date:
Research Org.:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Org.:
USDOE Office of Science (SC)
OSTI Identifier:
1119253
Report Number(s):
BNL-101911-2013-IR
DOE Contract Number:  
AC02-98CH10886
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS

Citation Formats

Stevens, A. J. Improved Estimates of Fault Dose Exterior to the PHENIX South Side Shield Configuration. United States: N. p., 1999. Web. doi:10.2172/1119253.
Stevens, A. J. Improved Estimates of Fault Dose Exterior to the PHENIX South Side Shield Configuration. United States. doi:10.2172/1119253.
Stevens, A. J. Wed . "Improved Estimates of Fault Dose Exterior to the PHENIX South Side Shield Configuration". United States. doi:10.2172/1119253. https://www.osti.gov/servlets/purl/1119253.
@article{osti_1119253,
title = {Improved Estimates of Fault Dose Exterior to the PHENIX South Side Shield Configuration},
author = {Stevens, A. J.},
abstractNote = {This note presents the results of more detailed calculations intended to estimate the distance away from the shield wall where high occupancy would be permissible.},